About the water softener system.

On

LAST RECHARGE

WATER MANAGEMENT SYSTEM

Turbine

Switch Turbine count

Valve

Minutes of cycle

position

remaining

Fill

TIME

WATER MANAGEMENT SYSTEM

Turbine

RECHARGE

WATER MANAGEMENT SYSTEM

x 10

DAY

Service: Manually Initiated Electronic Diagnostics

1 To enter diagnostics, press and hold the DATA button until the display appears as shown.

NOTE: If the softener is in the middle of a regeneration, top part of the display shows the cycle of regeneration and minutes of the cycle remaining. If two cycle names are flashing, the valve is in transition between the cycles.

AThe three digits under WATER MANAGEMENT SYSTEM indicate water meter operation as follows:

000 (steady) = soft water not in use…no flow through the meter.

—OPEN A NEARBY SOFT WATER FAUCET—

000 to 140 (continual) = repeats display for each gallon of water passing through the meter.

 

Motor

Position

 

switch

 

 

Sensor

 

housing

 

Turbine

Valve

Turbine

support

outlet

& shaft

If you don’t get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the turbine for binding.

B This display segment ( ), in the following chart, indicates an open POSITION switch. Use the TOUCH or HOLD button to manually advance the valve into each cycle and check correct switch operation.

CORRECT SWITCH

 

 

DISPLAYS

VALVE CYCLE STATUS

 

 

 

 

 

Valve in service, fill, brining, backwash

 

 

 

 

 

or fast rinse position.

 

 

 

 

 

Valve rotating from one position to another.

 

 

 

 

 

 

 

 

 

 

 

 

2 Press the DATA button again. This diagnostic display shows the total number of recharges (top) since the timer was connected to electrical power.

The number of days since the timer was connected to electrical power is shown in the bottom part of the display. If over 1999 days, a (x10) indicator shows, meaning you must multiply the number shown by 10.

3 Press DATA once again to return the present time to the display.

18

Page 18
Image 18
GE GNSF39A01, GNSF48A01 installation instructions Open a Nearby Soft Water Faucet