Touch or Hold button

RECHARGE TONIGHT

TOUCH

 

 

 

 

 

RECHARGE NOW

or

 

Up (+) button

HOLD

 

 

 

TIME

 

 

SET

 

 

HARDNESS

Set button

 

 

 

 

 

 

 

 

Down (–) button

Display

 

 

 

 

DATA

REMAINING CAPACITY

 

 

FLOW RATE GPM

 

 

GALLONS TODAY

 

Excel

 

AVG. DAILY GALLONS

Data button

 

 

 

 

 

Programming the Control

Timer settings required—upon installation and after an extended power outage.

NOTE:

When the transformer is plugged into the electrical outlet, 12:00 AM is flashing and the words PRESENT TIME show in the upper display area. Program the timer as instructed below. If, A---is flashing, see the Setting Model Code section.

A beep sounds while pressing buttons for timer programming. One beep signals a change in the timer display. Repeated beeps means the timer will not accept a change from the button or arrow you have pressed and you should use another.

To program the timer, you will use the SET, UP (+) and DOWN (-)buttons.

Set present time of day

NOTE: If the words PRESENT TIME do not show in the display, press the SET button until they do.

1

Press the UP (+) or DOWN (-)button to set. The UP button

moves the display ahead; the DOWN button moves the

time backward.

NOTE: Each press of an UP or DOWN button changes the time by 1 minute. Holding the buttons in changes the time 32 minutes each second.

AM

PRESENT TIME

If the present time is between noon and midnight, be sure PM shows.

If the present time is between midnight and noon,be sure AM shows.

2 When the present time shows, press SET to apply.

Set water hardness number

NOTE: If 15 (factory default) and HARDNESS do not show in the display, press the SET button until they do.

 

 

HARDNESS

 

1

 

 

 

Press the UP (+) or DOWN (-)button to set your water

hardness number in the display. The DOWN button

moves the display down to 1. The UP button moves the display up to 110.

NOTE: Each press of an UP (+) or DOWN (-)button changes the display by 1 between 1 and 25. Above 25, the display changes 5 at a time (25, 30, 35, etc.). Holding a button in changes the numbers twice each second.

2 When your water hardness number shows, press SET to apply.

NOTE: If there is clear water iron in your water supply, you will need to increase the hardness setting by 5 for each 1 ppm of clear water iron in your water supply.

You can get the grains per gallon (gpg) hardness of your water supply from a water analysis laboratory, or call and ask your local water department, if you are on a municipal supply, or call GE Answer Center® to request a water hardness test kit. If your report shows hardness in parts per million (ppm) simply divide by 17.1 to get the equivalent number of grains per gallon.