Installation Instructions

PLANNING FOR VENTING

INTAKE/EXHAUST GUIDELINES

Refer to the specific instructions on your vent

• Venting should be as direct as possible with

product for additional installation requirements.

a minimum number of pipe fittings.

• This water heater is a direct vent water heater and

• Vent diameter must not be reduced.

therefore is certified and listed with the vent system.

• Do not connect the venting system with

You must use vent components that are certified

an existing vent or chimney.

and listed with the water heater model. See

• Do not connect vent with the vent pipe of any other

approved venting list on page 20.

• Do not combine vent components from different

water heater or appliance.

• Vent connections must be firmly pressed together

manufacturers.

• The vent system must vent directly to

so that the gaskets form an air-tight seal.

• The vent piece connected to the water heater must

the outside of the building and use outside

air for combustion.

be secured with one self-tapping screw.

• Every vent connection must be accessible for

• Refer to the vent pipe manufacturer’s instructions

inspection, cleaning and replacement.

for component assembly instructions.

• Avoid dips or sags in horizontal vent runs by

• It is recommended to install an optional inlet screen

installing supports per the vent manufacturer’s

to minimize blockage and maintenance from debris.

instructions.

See page 20.

• Support horizontal vent runs every four feet

 

and all vertical vent runs every six feet or in

 

accordance with local codes.

 

5

Page 5
Image 5