Installation Instructions
FLUE TERMINAL CLEARANCES
|
| U.S. INSTALLATIONS |
|
| CLEARANCES PER |
REF | DESCRIPTION | ANSI Z21.10.3 |
A | Clearance above grade, veranda, porch, deck or snowline | 36 inches (91 cm) |
B | Clearance to window or door that may be opened | 12 inches (30 cm) |
C | Clearance to permanently closed window | * |
D | Vertical clearance to ventilated soffit, located above the terminal within | * |
| a horizontal distance of 2 feet (61 cm) from the center line of the terminal |
|
E | Clearance to unventilated soffit | * |
F | Clearance to outside corner | * |
G | Clearance to inside corner | * |
H | Clearance to each side of center line extended above meter/regulator | * |
| assembly |
|
I | Clearance to service regulator vent outlet | * |
J | Clearance to nonmechanical air supply inlet to building or | 12 inches (30 cm) |
| the combustion air inlet to any other appliance |
|
K | Clearance to a mechanical air supply inlet | 3 feet (91 cm) above |
|
| if within 10 feet |
|
| (3 m) horizontally |
L | Clearance above paved sidewalk or paved driveway located on public property1 | * |
M | Clearance under veranda, porch, deck or balcony2 | * |
*For clearancesnot specifiedin ANSI Z223.1/NFPA54, clearancesare in accordancewith localinstallationcodesand the requirementsof the gas supplier. Clearanceto oppositewallis 24 inches(60 cm).
1 A ventshallnot terminatedirectlyabovea sidewalkor paveddrivewaythat is locatedbetweentwo singlefamilydwellingsand servesboth dwellings.
2 Permittedonly if veranda,porch,deck or balconyis fullyopen on a minimumof two sidesbeneaththe floor.
FLUE TERMINAL CLEARANCES (ANSI Z21.10.3 • CSA 4.3) |
6 |