Installation Instructions

FLUE TERMINAL CLEARANCES

 

 

U.S. INSTALLATIONS

 

 

CLEARANCES PER

REF

DESCRIPTION

ANSI Z21.10.3

A

Clearance above grade, veranda, porch, deck or snowline

36 inches (91 cm)

B

Clearance to window or door that may be opened

12 inches (30 cm)

C

Clearance to permanently closed window

*

D

Vertical clearance to ventilated soffit, located above the terminal within

*

 

a horizontal distance of 2 feet (61 cm) from the center line of the terminal

 

E

Clearance to unventilated soffit

*

F

Clearance to outside corner

*

G

Clearance to inside corner

*

H

Clearance to each side of center line extended above meter/regulator

*

 

assembly

 

I

Clearance to service regulator vent outlet

*

J

Clearance to nonmechanical air supply inlet to building or

12 inches (30 cm)

 

the combustion air inlet to any other appliance

 

K

Clearance to a mechanical air supply inlet

3 feet (91 cm) above

 

 

if within 10 feet

 

 

(3 m) horizontally

L

Clearance above paved sidewalk or paved driveway located on public property1

*

M

Clearance under veranda, porch, deck or balcony2

*

*For clearancesnot specifiedin ANSI Z223.1/NFPA54, clearancesare in accordancewith localinstallationcodesand the requirementsof the gas supplier. Clearanceto oppositewallis 24 inches(60 cm).

1 A ventshallnot terminatedirectlyabovea sidewalkor paveddrivewaythat is locatedbetweentwo singlefamilydwellingsand servesboth dwellings.

2 Permittedonly if veranda,porch,deck or balconyis fullyopen on a minimumof two sidesbeneaththe floor.

FLUE TERMINAL CLEARANCES (ANSI Z21.10.3 • CSA 4.3)

6

Page 6
Image 6
GE GP94DNSRSA, GN94DNSRSA, GN75DNSRSA warranty Flue Terminal Clearances Ansi Z21.10.3 CSA