Preparing the Opening
Safety
Allow 3.81 cm (11⁄2″) spacing from the range to adjacent vertical walls above cooktop surface.
Allow 76.2 cm (30″) minimum clearance between surface units and bottom of unprotected wood or metal top cabinet, and 38.1 cm (15″) minimum between countertop and adjacent cabinet bottom.
EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
If cabinet storage is installed, reduce risk by installing a range hood that projects horizontally a min. of 12.7 cm (5″) beyond the bottom of the cabinets. Make sure the wall covering, countertops and cabinets around the range can withstand heat generated by the range, oven or cooktop up to 93°C. (200°F.).
Instructions Operating
Not less than the width
of the range
Instructions
76.2 cm
(30″) Min.
Wall
38.1cm
(15″) Min.
3.81cm
(11⁄2″)
Min.
Wall
Outlet box
Install the outlet box on either
side of the C L
Hood
12.7 cm (5″) Min.
Locate the outlet box within either shaded area.
C of range |
| |
L |
| |
19.05 cm |
| |
(71⁄2″) |
| |
17.78 cm | 19.05 cm | |
(7″) | ||
(71⁄2″) | ||
8.89 cm |
|
(31⁄2″) | 12.7 cm (5″) |
| |
| Floor |
| 5.72 cm |
| (21⁄4″) |
Care and Cleaning Installation Instructions Troubleshooting
Cord