1 PROVIDE ADEQUATE GAS SUPPLY

Your range is designed to operate at a pressure of 4″ of water column on natural gas or, if designed

Gas Pipe and Electric Outlet Locations for Models Equipped with Sealed Burners

for LP gas (propane or butane), 10″ of water column. Make sure you are supplying your range with the type of gas for which it is designed. This range is convertible for use on natural or propane gas, if you decide to use this range on a different type of gas, conversion adjustments must be made by a service technician or other qualified person before attempting to operate the range on that gas.

For proper operation, the pressure of natural gas supplied to the regulator must be between 4″ and 13″ of water column. For LP gas, the pressure supplied must be between 10″ and 13″ of water column. When checking for proper operation of the regulator, the inlet pressure must be at least 1″ greater than the operating (manifold) pressure as given above. The pressure regulator located at the inlet of the range manifold must remain in

This area allows for flush range installation with through-the-wallconnection of pipe stub/shut-off valve and rear wall 120V outlet.

Shortest connection from hard pipe stub location to range hookup.

4"

9"

30"

212" 4" 8"

24"

2"

61" C

4 L

the supply line regardless of whether natural or LP gas is being used. A flexible metal appliance connector used to connect the range to the gas supply line should have an I.D. of 1/2″ and be

5 feet in length for ease of installation. In Canada, flexible connectors must be single wall metal connectors no longer than 6 feet in length.

This area allows for flush range installation with through-the-floor connection of pipe stub/shut-off valve.

Gas Pipe and Electric Outlet Locations for Models Equipped with Standard Twin Burners

2 CONNECT THE RANGE TO GAS

Shut off the main gas supply valve before disconnecting the old range and leave it off until new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.

Because hard piping restricts movement of the range, the use of an A.G.A.-certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection. Never use an old connector when installing a

This area allows for flush range installation with through-the-wallconnection of pipe stub/shut-off valve and rear wall 120V outlet.

30"

4" 8" 7"

29"

Shortest connection from hard pipe stub location to range hookup.

new range. If the hard piping method is used, you must carefully align the pipe; the range

24"

2"

cannot be moved after the connection is made.

To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.

*Teflon: Registered trademark of DuPont

9"

212"

C

L

This area allows for flush range installation with through-the-floorconnection of pipe stub/shut-off valve.

(continued next page)

37

Page 37
Image 37
GE JGBP38 installation instructions Provide Adequate GAS Supply, Connect the Range to GAS