PROBLEM

POSSIBLE CAUSE

 

 

“F—AND A NUMBER”

• If the time display flashed “F—and a number,” you have a function error code.

FLASH IN THE DISPLAY

If a function error code appears during the self-cleaning cycle, check the oven

 

door latch. The latch handle may have been moved, even if only slightly, from

 

the latched position. Make sure the latch is moved to the right as far as it will go.

 

Press the CLEAR/OFF pad. Allow the oven to cool for one hour. Put the oven

 

back into operation.

 

 

 

• Disconnect all power to the range for 5 minutes and then reconnect power.

 

 

 

If the failure code repeats, then call for service.

 

 

 

 

 

 

 

 

 

OVEN WILL NOT WORK

• Plug on the range is not completely inserted in the electrical outlet.

 

 

 

• Pilot(s) is (are) not lit (on standing pilot models). See the Lighting Instructions

 

for Standing Pilot Models in Using Your Oven.

 

 

 

• The circuit breaker in your house has been tripped, or a fuse has been blown.

 

• Oven controls not properly set.

 

 

 

 

 

 

 

 

 

SURFACE BURNERS

• The oven gas shut off valve may have accidentally been moved during

 

 

LIGHT BUT OVEN

cleaning or moving.

 

 

DOES NOT

To check the oven gas shut off valve on standard twin burner models, raise

 

 

 

 

 

 

the cooktop and look for the gas shut off lever at the extreme right rear corner.

 

(Standing pilot models do not have a gas shut-off valve on the regulator.)

 

 

 

Follow the directions in box A or B that match your regulator type.

 

 

 

 

 

 

 

 

 

 

A

 

B

Lever shown closed.

Lever shown closed.

PULL TO OPEN.

PULL TO OPEN.

 

Standard Twin Burner Models

Standard Twin Burner Models

To check the oven gas shut off valve on sealed burner models, remove the storage drawer, broiler drawer or kick panel and look for the gas shut off lever at the back of the range. On some models you may have to remove an access cover also.

Follow the directions in box A or B that match your regulator type.

A

Lever

B

 

shown closed.

 

 

PULL TO OPEN.

 

Lever shown closed.

PULL TO OPEN.

Sealed Burner Models

Sealed Burner Models