GE JGP319 CInstalling the Cooktop, C1 ProvideSupply Adequate Gas, C3 Installing the Regulator

Models: JGP321 JGP319

1 64
Download 64 pages 4.56 Kb
Page 18
Image 18
CInstalling the Cooktop

Installation Instructions

CInstalling the Cooktop

C1 ProvideSupply Adequate Gas

This cooktop is designed to operate on natural gas at 4of water column pressure. It is shipped from the factory set for natural gas (except JGP319 models, which are set for LP). The convertible pressure regulator supplied with the unit must be connected in series with the manifold of the cooktop and must remain in series with the supply line regardless of whether natural or L.P. gas is being used.

FOR PROPER OPERATION, THE MAXIMUM INLET PRESSURE TO THE REGULATOR MUST BE NO MORE THAN 14OF WATER COLUMN PRESSURE. For checking the regulator, the inlet pressure must be at least 1(or 3.4 KPA) greater than the regulator output setting. If the regulator is set for 4of water column pressure, the inlet pressure must be at least 5. If the regulator is set for 10, the inlet pressure must be at least 11.

The gas supply line to the cooktop should be 1/2or 3/4pipe.

C3 Installing the Regulator

NEVER REUSE OLD CONNECTORS WHEN INSTALLING THIS COOKTOP.

WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use new flexible connectors when installing a gas appliance.

Screw a section of pipe

Pressure

onto each end of the

Regulator

pressure regulator.

 

To reduce the likelihood of gas leaks, apply teflon tape or a thread compound approved for use with LP or natural gases to all threaded connections.

C4 Install the regulator onto the burner box bottom

C2 Locate the electrical outlet and the Gas Shut Off valve beneath the cabinet.

NEVER REUSE

 

 

OLD CONNECTORS

 

 

WHEN INSTALLING

 

 

THIS UNIT.

Shut Off

Electrical

 

Valve

Outlet

 

 

12" Below

 

 

Countertop

Install a manual shutoff valve in the gas line in an easily accessible location outside the cooktop. Be sure you know how and where to shut off the gas supply to the cooktop. Install the electrical outlet 12below the countertop.

Screw the regulator and pipe connection into the burner box bottom. Make sure the top of the regulator is facing toward the cabinet front, easily accessible through the cabinet doors.

Pressure

 

Regulator

 

Shut Off

Electrical

Valve

Outlet

 

12" Below

 

Countertop

18

Page 18
Image 18
GE JGP319 CInstalling the Cooktop, C1 ProvideSupply Adequate Gas, C3 Installing the Regulator, Installation Instructions