DATA DESCRIPTION OF DEFAULT ZONE TYPES
11 KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel that it resides in
each time the zone is shorted. Keyswitch arming will report as user #99.
12
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED -This zone will be instant when the system is armed and no
entry or exit delay is being timed. It is delayed during entry and exit delay times. If a "Cross Zone" is not being timed it will
start a "Cross Zone" timer. If a "Cross Zone" is being timed it will create an instant alarm. This zone will automatically
bypass when enabled in Segment 1 of Location 23.
13 INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED is off. It will start
an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
14
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED -A trip will start entry delay 1. This zone will bypass when
the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay will enable the Automatic
Bypass or Instant mode if so programmed.
15
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is armed and no
entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the "Group
Bypass" command is entered at the keypad. This zone will automatically bypass if enabled in Segment 1 of Location 23.
16 INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is tripped and the Armed
LED is on. This zone will bypass when the "Group Bypass" command is entered at the keypad.
17
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start entry delay 1. The lack of a trip during exit delay will
enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a
wireless transmitter.
18
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED -This zone will be instant when the system is
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will
automatically bypass if enabled in Segment 1 of Location 23. This zone type can be used to enable tamper on a
wireless transmitter.
19 INSTANT WITH TAMPER ENABLED -This zone creates an instant alarm whenever it is tripped and the Armed LED is
on. This zone type can be used to enable tamper on a wireless transmitter.
20
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry delay 2. The lack of a trip during exit delay will
enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a
wireless transmitter.
21 GAS DETECTION- Creates an instant alarm regardless of the armed state of the control panel. It will display on the
keypad and activate the keypad sounder.
22 LOW TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control panel. It will display
on the keypad and activate the keypad sounder.
23 HIGH TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control panel. It will
display on the keypad and activate the keypad sounder.
24 MANUAL FIRE - This zone will illuminate the Fire LED and sound the temporal siren each time the zone is shorted. It will
also rapidly flash the Fire LED indicating a trouble if the zone is open.
25 CHIME ONLY - Creates no alarm regardless of the armed state of the control panel. It will chime anytime it is faulted and
will display on the keypad. Local only.
26
INTERIOR FOLLOWER DELAY 2 - This zone will be instant when the system is armed and no entry or exit delay is
being timed. It is delayed during entry and exit delay 2 times. This zone will automatically bypass if enabled in Segment 1
of Location 23.
27
INTERIOR FOLLOWER FORCE ARMABLE -This zone will be instant when the system is armed and no entry or exit
delay is being timed. It is delayed during entry and exit delay 1 times. This zone will automatically bypass if enabled in
Segment 1 of Location 23.
28 ENTRY/EXIT FORCE ARMABLE DELAY 2 - A trip will start entry delay 2. The lack of a trip during exit delay will enable
the Automatic Bypass or Instant mode if so programmed.
29
INTERIOR FOLLOWER WITH ACTIVITY SUPERVISION ENABLED - This zone will be instant when the system is
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. It will send a report if the
zone activity time is reached without a change of state. Refer to Location 40 / Segment 11. This zone will automatically
bypass if enabled in Segment 1 of Location 23.
30
ENTRY/EXIT WITH ACTIVITY SUPERVISION ENABLED-A trip will start entry delay 1. It will send a report if the zone
activity time is reached without a change of state. Refer to Location 40 / Segment 11. The lack of a trip during exit delay
will enable the Automatic Bypass or Instant mode if so programmed.
L 25 ZONES 1-8 ZONE TYPE 8.............numerical
Location 25 contains the Zone Type for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8. Default Zone Types are
found in the table on page 16. To customize a Zone Type, see page 28.
26 PARTITION SELECT, ZONES 1-8 8............. feature select
Location 26 is used to select the partition(s) that zones 1 - 8 reside in. A zone may reside in any combination of the 8 partitions. If a
burglary zone resides in more than 1 partition, it will only be active when all partitions it resides in are armed. A zone that
resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1
corresponds to zone 1, and Segment 8 corresponds to zone 8.