NX-8V2 Control 27
102 PARTITION 6 FEATURE & REPORTING SELECTIONS 5.............feature select
Location 102 is used to enable certain features that can be accessed or are visible to the user from the keypad of the system. In
addition, certain communicator reports are enabled in this location. Each of these features can be enabled by partition. This location
contains 5 segments, with eight possible features per segment. Refer to Location 23 (page 15) for the feature selections. If all
segments are blank (nothing enabled), the features for partition 1 will be used.
103 PARTITION 6 ENTRY EXIT TIMERS 6.............numerical
Location 103 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid entries are 10-255
seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry Time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit Time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry Time 2: Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit Time 2: Exit time that will be used for all zones designated as Delay 2.
Segments 5 & 6: Reserved
104 ACCOUNT CODE FOR PARTITION 7 6.............numerical
The account code sent when partition 7 is reported is programmed in location 104. If location 104 is left unprogrammed (all A10")
then the account code corresponding to the Phone number dialed will be used. If the account code is less than six digits,
program a A10" in the segment immediately after the last digit of the account code. If the account code is 6 digits long, program all 6
segments.
105 PARTITION 7 FEATURE & REPORTING SELECTIONS 5.............feature select
Location 105 is used to enable certain features that can be accessed or are visible to the user from the keypad of the system. In
addition, certain communicator reports are enabled in this location. Each of these features can be enabled by partition. This location
contains 5 segments, with eight possible features per segment. Refer to Location 23 (page 15) for the feature selections. If all
segments are blank (nothing enabled), the features for partition 1 will be used.
106 PARTITION 7 ENTRY EXIT TIMERS 6.............numerical
Location 106 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid entries are 10-255
seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry Time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit Time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry Time 2: Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit Time 2: Exit time that will be used for all zones designated as Delay 2.
Segments 5 & 6: Reserved
107 ACCOUNT CODE FOR PARTITION 8 6.............numerical
The account code sent when partition 8 is reported is programmed in location 107. If location 107 is left unprogrammed (all A10")
then the account code corresponding to the Phone number dialed will be used. If the account code is less than six digits,
program a A10" in the segment immediately after the last digit of the account code. If the account code is 6 digits long, program all 6
segments.
108 PARTITION 8 FEATURE & REPORTING SELECTIONS 5.............feature selecti
Location 108 is used to enable certain features that can be accessed or are visible to the user from the keypad of the system. In
addition, certain communicator reports are enabled in this location. Each of these features can be enabled by partition. This location
contains 5 segments, with eight possible features per segment. Refer to Location 23 (pg 15) for the feature selections. If all segments
are blank (nothing enabled), the features for partition 1 will be used.
109 PARTITION 8 ENTRY EXIT TIMERS 6.............numerical
Location 109 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid entries are 10-255
seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry Time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit Time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry Time 2: Entry time that will be used when a Delay 2 zone type initiates an entry Delay.
Segment 4, Exit Time 2: Exit time that will be used for all zones designated as Delay 2.
Segments 5 & 6: Reserved