48 NX-8V2 Control
Keyswitch Arm/Disarm
Any zone on the NX-8V2 can be programmed as a keyswitch zone. If this is done, a momentary short on this zone will arm/disarm the
control. If opening/closing reports are sent, the user code will be 99. (See "Default Zone Types", pg 16)
LED Extinguish
This feature will extinguish all LEDs on the keypad, except the "Power" LED, after 60 seconds without a keypress. Pressing any
numeric key will illuminate all LED=s. (Loc 23, pg 15)
Local Programming Lockout
This feature will disable programming of all locations or specified locations from the keypad. (Loc 21, pg 15)
Log Full Report
A report can be sent to the central station when the event log is full. (Loc 37, pg 19)
Lost Clock Service Light
The NX-8V2 can be programmed to illuminate the "Service" LED when the internal clock has an invalid time due to power loss. (Loc
37, pg 19)
Manual Test
The NX-8V2 can be programmed to perform a bell and/or communicator test when r44 is entered while the system is in the
disarmed state. (Loc 37, pg 19)
Night Mode
NOTE: This mode applies to NX1208E / NX1248E keypads.
In this mode, the control panel will bypass all zones that have the Entry Guard feature enabled. (Loc 23, pg 15)
On Board Zone Disable
The 8 zones on the NX-8V2 panel can be disabled in order to have a completely wireless alarm system. (Loc 37, pg 19)
Partitions
The NX-8V2 can be partitioned into a maximum of eight separate systems with distinct reporting codes, user codes, and operating
features for each system. (Loc 26 - 36, pg 17-19)
Program Code
The factory default for the "Go To Program" code is 9713 when using a 4-digit code or, if the 6-digit option is used, the default is
971300. The program code can also be used as an Arm/Disarm code. If used as an Arm/Disarm code, and open/close re ports
are sent, the user code will be 255. (Loc 43, pg 21)
Quick Arm Feature
The NX-8V2 has a one-button "Quick Arm" feature which can be used to arm the system by pressing the [Exit] key or the [Stay] key on
the keypad. If closing reports are sent, the user code will be 98. (Loc 23, pg 15)
Recent Closing
If enabled, the NX-8V2 will send a "Recent Closing Report" to the central station if an alarm occurs within 2 minutes after the panel is
armed. The user number that armed the system will also be sent. (Loc 23, pg 15)
Re-exit
The NX-8V2 has the ability to restart the exit delay for a quick exit without disarming the system by pressing the [Exit] key while the
system is armed. (Loc 23, pg 15)
Shutdown
When enabled, the keypads will turn off all LED=s, except the "Power" LED, and not accept keypresses. (Loc 21, pg 15)
Siren Blast For Arming
The NX-8V2 can be programmed to give a one-second siren blast when the panel is armed, at the end of the exit delay, or when the
central station receiver acknowledges the closing report. It can also give one blast for remote (keyswitch) arming and two blasts for
remote disarming. (Loc 37, pg 19)
Siren Supervision
The NX-8V2 has a ASiren Supervision@ circuit that will constantly monitor the siren on the NX-8V2 and can be programmed to report if
the wires are cut. (Loc 37, pg 19)
Silent Exit Option
The exit delay can be silenced by pressing [r]-[Exit] before arming the control panel or when using the re-exit feature.
Start / End Programming and End Downloading
A report can be sent when local programming is started and ended. A report can also be sent when a download session ends. (Loc
37, pg 19)
Swinger Shutdown
This feature allows a zone or zones to be automatically bypassed after a specified number of alarms. When a zone is tripped, the alarm
‘counter’ reflects “1” in memory. If a new (first) alarm is detected in a different zone, the counter remains at “1”. If an alarm is detected
on a previously tripped zone, the count increments to “2”. The ‘counter’ will increment each time an alarm is detected on a zone with
multiple trips. Bypassing will occur on the zone that causes the count to equal the number programmed in location 38; the ‘counter’ will
reset to zero (0); and begin a new trip count where the next alarm will set the ‘counter’ to 1. If immediate restore is enabled in location
37, the alarms (and restores, if enabled) will be sent as they occur. If immediate restore is not enabled, a second or subsequent alarm
will not be sent until the siren times out. Factory default is 1. (Loc 37 & 38, pg 19)
Telephone Line Monitor
The NX-8V2 has a Telephone Line Monitor that monitors the voltage and current of the telephone line for a detection of a faulted phone
line. This condition can also be reported to the central station. If the report is enabled, only the Telephone Line Restore will be reported .
(Loc 37, 39, & 40, pg 19-20)
Temporal Siren Disable NOTE: For UL installations, do NOT disable.
If disabled, the Fire Siren will be steady and Fire Voltage Out will be the same as Burglary (continuous). Otherwise, the Fire Siren will
be temporal. (Loc 37, pg 19)