Installation Instructions
Convert Natural Gas to LP Gas Operation
Convert LP Gas to Natural Gas Operation
be performed by a qualified installer or gas supplier in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction.Failureto follow instructions couldresult in seriousinjury or property damage. The qualified agencyperforming this work assumes responsibility for the conversion.
WARNING:The rangetop, as shipped from the factory, is set for use with its intended gas.If you wishto use yourrangetop with the alternate gas,you must first replace the orifices and convertthe pressure regulator.
WARNING:The following adjustments mustA. Remove the rear vent Range Regulator
trim (on ranges only) to access the regulator. The
Rangetop regulator is on the left bottom
corner.
B.Shut off the gas supplyby closing the manual
C.Convert the pressureregulator:
•Unscrew the cap with plunger.
•Place your thumb against flat side of the plunger and press down to snap the plunger out of the cap.
•Carefully look at the plunger to locate the NAT or LP position.
be madebefore turning on the burner. Failureto do so couldresult in serious injury. Be sure pressureregulator has beenconverted as described in Step 2.
TOOLS YOU NEEDED FOR CONVERSION•Turn the plunger over so that the desired gas is showing near the bottom.
•Snap the plunger back into the cap.
•Screw the cap back onto the regulator.
Cap | Gasket |
LP | ATN |
NAT | |
| LP |
| Plunger |
LP | NAT |
NAT | LP |
NAT. LP Position Position
FOROFF
DOWN
Crescent Wrench | 1/4” and 7mm Nutdrivers |
| |
| Small |
Pressure Regulator
3 CHANGE BURNER ORIFICES
| Safety Glasses |
| (2 to 2.4 mm or 3/32” tip size, | |
|
| 60 mm long) | ||
|
|
| ||
|
|
|
| Philips |
| 1/2” Deepwell | Small Pliers | Screwdriver | |
| Socket Wrench |
|
|
|
1 | ORIFICE HOLDER | Griddle | Grill | |
Orifice | Orifice |
The range orifice holder is located behindthe front access panel at the bottom of the range.
The rangetop orifice holder
is located insidethe range insulation cover.
Additional orificesmay be present. Use onlythe orifices specified in the instructions for your range or rangetop.
INSTALLATION TIP: First remove all orifices and then start replacing them. This will help to prevent the possibility that some may not be replaced.
Burner
A. Remove the burner grates, Head burner caps and burner heads.
B. Loosen the top burner orifices using a 7 mm nut driver.Use small
pliers to carefullyliftout the orifices.
The main orifice is located low in the center of the burner, while the simmer
orifice is located higher beside the center of the burner.
Burner Cap
Burner Base
Simmer
Orifice
15