Installation Preparation
| Drill and |
Saber Saw | Appropriate Bits |
| |
Measuring Tape | Adjustable Wrench |
| |
| 1/4" Driver or Wrench |
Carpenter’s Square |
|
Safety Glasses
Phillips #2 Screwdriver
Level | Hand Truck |
|
Regulator | |
Strap |
|
Joint | Pipe Fittings | |
Sealant |
|
|
flexible metal gas supply
•The natural gas models are designed to operate at 5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
•The LP models are designed to operate at 10" water column pressure. For proper operation, the pressure
of the LP gas supplied to the regulator must be between 11" and 13" water column.
•Locate the pipe stub on the back wall or floor
(see “Product Dimensions and Clearances”). Use
•Install a manual
(not provided), in an easily accessible location. Make sure the homeowner knows where and how to shut off the gas supply to the rangetop.
These rangetops must be supplied with 120 volt, 60 Hz., and connected to a dedicated, properly grounded branch circuit protected by a 15 amp circuit breaker or time delay fuse.
The power cord of this appliance is equipped with a
If the electrical service provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT
OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.
DO NOT USE AN EXTENSION
CORD WITH THIS APPLIANCE.
• Locate the electric supply
within the area shown or within reach of the rangetop’s
•To avoid tangling cord with items stored in the cabinet, locate the receptacle on rear wall, inside the cabinet.
7