Installation Instructions for Gas Conversion

5 CHANGE GRIDDLE ORIFICE (if present)

Locate the3/4” longgriddle orifice.

Selectforyour gastype. LP.047, NAT.076

A. Lift off the

Griddle Flue Cover

 

griddle flue

 

cover. Remove

A

 

the 2 inside

 

 

clamping

 

 

screws.

 

 

B. Lift out the

 

NOTE: Remove

cast-iron

 

grease trough.

Leveling Screws

the 2 screws

positioned on

Slide the

 

the inside only.

griddle toward

 

Do not remove

the rear and

Clamping Screws

the outermost

screws—they

out of the

 

are for leveling.

hold-down

 

tabs along the

B

bottom.

 

C. Carefully lift and hold

 

the griddle while pulling

 

additional length of the

 

capillary from the entry

 

hole. Stand the griddle on

 

end in the grease sump.

 

D. Remove the 2 hold-down

C

screws at the rear of the

Capillary

burner.

Pull the burner straight back toward the rearand out of the gas inlet.

E.Use a 1/2deepwell socket to remove and replace the orifice.

D

Back of Range

E

Front of Range

Reverse these steps to reassemble the griddle. Push excess capillary back into the entryhole. Place the unused orificein the holder for possible future use.

6 ADJUST BURNER FLAMES

Normally, burners donot needfurther adjustment. Make adjustmentsonly when necessary.

A.Turn on the gas. Plug in electrical cord.

B.Turn all burners on highest setting and check the flames. They should be blue in color.When using LPgas, the flames may have some yellow tipping at the ends of the flame. Foreign particles in the gas line may cause an orange flame at first, but this will soon disappear.

C.Turn the burner knob to “LO” while observing the flame.

Adjust the setting of the upper row of flames using the valve bypass screw as follows:

Adjustments must be made with two other burners in operation on a medium setting. This prevents the upper row of flames from being set too low, resulting in the flame being extinguished when other burners are turned on.

D. To adjust the flame, removethe knobs.Insert a small flat-blade screwdriver into the hole in the center

of the valvestem to engage screw.

If the flames are too small or flutter, turn the screw counterclockwise.

If the flames are too large, turn the screw clockwise.

E.Make the adjustment by slowly turning the screw until flame appearance is correct.

Once the conversion is completeand checked,fillout the conversionlabel and affix the label near the ratinglabel.For ranges, place the label beneath the controlpanel. For rangetops,place the label on the bottom of the unit.

17