Installation Instructions
3 INSTALL THE HOOD
Place the hood on the brackets and slide left to right to align with rectangular slots at the top.
Screws “B”
To Secure Hood
To Wall
Level and
Height
Adjustment
Screws “A”
•Adjust the installation height by tightening or loosening the screws “A” at the bottom of the brackets.
Lower
Mounting Screws
•Align the hood lower mounting holes with pilot holes in the wall.
•Using two large flat washers (supplied), install wood screws or wall fastener screws, loosely, into lower mounting holes. Do not tighten.
•Level the hood by tightening or loosening the screws “A” located on the bottom mounting brackets.
•Tighten lower mounting screws.
•Tighten screws “B” located at the top of the mounting bracket against the hood to clamp the position. Do not overtighten screws.
4SIZE DUCT PIECE
•Hold upper air deflector with duct connector against the ceiling.
•Measure from the bottom of the support to top of the hood
as shown. Reduce |
| |
this dimension |
| |
by 1" to facilitate | Duct | |
installation. The | ||
Length | ||
duct will cover/ | ||
Measure | ||
overlap the deflector | ||
and the hood outlets. | Length | |
|
•Cut duct piece to size and slip onto the bottom of the duct connector.
•Use duct tape to secure duct piece to connector.
7
5 INSTALL AIR DEFLECTOR ASSEMBLY
•Place the assembly over the hood outlet.
•Hold the assembly against the ceiling. The penciled centerline should show through the slot on the deflector. Mark the two screw holes on the back of the assembly.
•Remove the assembly and
drill 1/8" pilot holes into the wall studs.
•Enlarge holes that did not enter studs to 3/8" and tap plastic or metal anchors into the
holes, flush with the wall.
• Mount the assembly onto the hood outlet,
push up against the ceiling and install the screws provided.
• Use duct tape to seal the connection.