Haier KC18AGH Notices For Installation, 7.1Basic Requirements for Installation Position

Models: KC18AGH SAP-K18AM

1 37
Download 37 pages 20.85 Kb
Page 23
Image 23
Installation Service

Installation Service

7. NOTICES FOR INSTALLATION

Important Notices

1.

The unit installation work must be done by qualified

 

personnel according to the local rules and this manual.

 

 

 

 

 

2.

Before install, please contact with local authorized

 

 

maintenance center. If the unit is not installed by the

 

 

authorized maintenance center, the malfunction may

 

 

not solved, due to discommodious contacts.

 

3.

When removing the unit to the other place, please

 

 

firstly contact with the authorized SANYO Maintenance

 

 

Center in the local area.

7.1Basic Requirements for Installation Position

Install in the following place may cause malfunction. If it is unavoidable contact with service center please:

1.Place where strong heat sources, vapors, flammable gas or volatile object are emitted.

2.Place where high-frequency waves are generated by radio equipment, welders and medical equipment.

3.Place where a lot of salinities such as coast exists.

4.Place where a sulfured gas such as the hot spring zones is generate.

5.Place where the oil (machine oil) is contained in the air.

6.Other place with special circumstance.

7.2Indoor Unit Installation Position Selection

1.The air inlet and outlet vent should be far from the obstruction, make sure that the air can be blown through the whole room.

2.Select a position where the condensing water can be easily drained out, and the places easily connected for outdoor unit.

3.Select a location where the children can not reach.

4.Can select the place where is strong enough to withstand the full weight and vibration of the unit. And will not increase the noise.

5.Be sure to leave enough space to allow access for routine maintenance. The height of installed location should be

200cm or more from the floor.6. Select a place about 1m or more away from TVset or any other electric appliances.

7.Select a place where the filter can be easily taken out.

8.Make sure that the indoor unit installation should accord with installation dimension diagram requirements. (Pg.24)

7.3Outdoor Unit Installation Position Selection

1.Select a location from which noise and outflow air emitted by unit will not inconvenience neighbours, animals, plants.

2.Select a location with sufficient ventilation.

3.Select a location where there should be no obstructions cover the inlet and outlet vent.

4.The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation.

5.Select a dry place, but do not expose under the direct sunlight or strong wind.

21

Page 23
Image 23
Haier KC18AGH, SAP-K18AM Notices For Installation, 7.1Basic Requirements for Installation Position, Installation Service