9.5How to Install the Indoor Unit

Installation Service

9.INSTALL INDOOR UNIT

9.5How to Install the Indoor Unit

For tubing, choose either the left side or right side direction.

1.When routing the piping and wiring from the left or right side of indoor unit, cut off the tailing from the chassis in necessary.

(As shown in Fig 20)

Cut off the tailings 1 when routing the wiring only.

Cut of the tailings 1 and tailings 2 when routing both the wiring and piping.

2.Take out the piping from body case, wrap the piping, electric wire, water pipe with tape and push them through the piping hole. (As show in Fig.21)

3.Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is securely seated on the rear panel. (As show in Fig.22)

4.Carefully bend the tubing (if necesasry) to run along the wall in the direction of outdoor unit and then tape as far as the fittings. (Refer 9.3 on Pg. 24). The drain hose should come staright down the wall to a point where water runoff won't stain the wall.

Tailing 2

Do not supply power tounit or operate it untilall tubing and wiring tothe outside unit arecompleted.Risk of Electric Shock Tailing 1

Fig.20

External connection electric wire

Gas side piping

 

Liquid side piping

Gas side piping

 

insulation

Liquid side piping

Finally wrap

insulation

it with tape

Water drainage

 

pipe

 

Left

Right

Left rear

 

Right rear

 

Fig.21

5.Connect the refrigerant tubing to the outdoor unit. (After performing a leak test on the connecting part, insulate it with the tubing insulation. (Fig.21) Also, refer to Pg 29, (connecting tubing between indoor and outdoor unit).

NOTE For stable operation of the air conditioner, do not install wall- mounted type indoor units less than 2.5m from the floor level. (Fig.23)

Fixing hook

Mounting board

Mounting

board

Fig. 22

Wall

Indoor unit

 

Do not supply power to

CAUTION

 

unit or operate it until

 

 

all tubing and wiring to

 

the outside unit are

 

completed.
Risk of Electric Shock

Minimum height from floor level 2.5m

Floor level

Fig.23

27