Installation Service
7. NOTICES FOR INSTALLATION
7.3Outdoor Unit Installation Position Selection (Continued)
6.Make sure that the outdoor unit installation dimension should accord with installation dimension diagram, convenient for maintenance, repair. ( See Pg.23)
7.The height difference of connecting the tubing within 5m, the length of connecting the tubing within 10m.
8.Select a place where it is not reachable for the children.
9.Select a place where will not block the passage and do not influence the city appearance.
7.4Safety Requirements for Electric Appliances
1.The power supply should be used the rated voltage and AC exclusive circuit, the power cable diameter should be satisfied.
2.Voltage applying range: the normal running range is rated
voltage 198V - 253V.
3.Don't drag the power cable emphatically.
4.It should be reliable eearthd and it should be connected to the special earth device, the installation work should be operated by the professional.
•The creepage protect switch and air switch with enough capacity must be installed in the fixing circuit.
•Air switch
5.The min. distance from the unit and combustive surface is 1.5m.
NOTE • The power supply position should be correctly connected, and that should be reliably connected, no internal short circuit.
• Wrong connection, may cause fire.
7.5Earthing Requirements
7.6 Others
1.Air conditioner is type 1 electric appliance, thus please do conduct reliable earthing measure.
2.The
3.The user power must offer the reliable earthing terminal. DO NOT connect the earthing wire with the bellow places:
-Gas pipe
-Tap water pipe
-Contamination pipe
-Other places that the professional personnel consider them unreliable.
1.The connection method of unit and power cable as well as the interconnection method of each isolated component should refer to the circuit diagram stick on the unit.
2.The model of the blown fuse and rated value should refer to the
3.The outside static pressure is 0MPa when the unit is testing.
22