Installation Service
9.INSTALL INDOOR UNIT
9.4.2Wire Length and Diameter
Regulations on wiring diameter differ from locality. For field wiring requirements, please refer to local electrical codes. Carefully observe these regulations when carrrying out the installation.
Table 1 lists the recommended and max. allowable wire lengths and diameters for the power supply system. Please refer to the wiring system diagram (Fig.18 &19) for the meaning of “A”, “B” and "C" in Table 1.
Table 1
|
| Recommended | Max. allowed | Fuse or circuit | |||||
area (mm2) | *(A) |
| *(B) | *(C) | (A) + (B) | *(C) | |||
| breaker capacity | ||||||||
Model | 2.5 x (3) | 2.5 x (4) | 0.75 x (2) | 2.5 | 0.75 | 1.0 | |||
| |||||||||
KC18AM | 1.8m |
| 5.0m | N.A | 32m | 20m | N.A | 20A | |
KC18AGH | 1.8m |
| 5.0m | 5.0m | 32m | 20m | 32m | 20A | |
*(A) Power supply wiring length (m) | ; | *(B) Power line length (m) | ; *(C) Control line length (m) |
CAUTION
•Be sure to connect the power supply line to the indoor unit as shown in the wiring diagram. The outdoor unit draws its power from the indoor unit.
WARNING
•Be sure to comply with local codes on running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.).
•Each wire must be firmly connected.
•No wire should be allowed to touch refrigerant tubing, the compressor, or any moving part.
WARNING
To avoid the risk of electric shock, each air conditioner unit must be grounded.
WIRING SYSTEM DIAGRAM
OUTDOOR |
| INDOOR | |
UNIT |
| (B) | UNIT |
Terminal |
| Terminal | |
Blue |
| ||
N(1) |
| N(1) | |
|
| ||
2 | Black |
| 2 |
|
| ||
3 | Brown |
| 3 |
|
| ||
|
|
| |
| (Grounding Line) | (A) |
|
|
|
| |
|
| L | L |
|
|
| |
| Power Supply | N | N |
| Single Phase | ||
|
|
| |
|
| P.C.B | |
| Grounding Line |
|
Fig. 18 (Cooling Model)
OUTDOOR |
| (B) | INDOOR | |
UNIT |
|
| UNIT | |
|
|
|
| |
| (Grounding Line) |
|
| |
N | Blue |
|
| N |
|
|
| ||
2 | Black |
|
| 2 |
|
|
| ||
3 | Brown |
|
| 3 |
| (C) |
| ||
| Violet |
|
| |
4 |
|
| 4 | |
|
|
| ||
5 | Orange |
|
| 5 |
|
|
| ||
Terminal |
|
|
| Terminal |
|
|
| (A) |
|
|
| L |
| L |
|
|
|
| |
| Power Supply | N |
| N |
| Single Phase |
| ||
|
|
|
| |
|
| P.C.B | ||
|
|
|
| |
|
| Grounding Line |
|
Fig. 19 (Heat Pump Model)
26