9.4.2Wire Length and Diameter

Installation Service

9.INSTALL INDOOR UNIT

9.4.2Wire Length and Diameter

Regulations on wiring diameter differ from locality. For field wiring requirements, please refer to local electrical codes. Carefully observe these regulations when carrrying out the installation.

Table 1 lists the recommended and max. allowable wire lengths and diameters for the power supply system. Please refer to the wiring system diagram (Fig.18 &19) for the meaning of “A”, “B” and "C" in Table 1.

Table 1

Cross-sectional

 

 

Recommended

Max. allowed

Fuse or circuit

area (mm2)

*(A)

 

*(B)

*(C)

(A) + (B)

*(C)

 

breaker capacity

Model

2.5 x (3)

2.5 x (4)

0.75 x (2)

2.5

0.75

1.0

 

KC18AM

1.8m

 

5.0m

N.A

32m

20m

N.A

20A

KC18AGH

1.8m

 

5.0m

5.0m

32m

20m

32m

20A

*(A) Power supply wiring length (m)

;

*(B) Power line length (m)

; *(C) Control line length (m)

CAUTION

Be sure to connect the power supply line to the indoor unit as shown in the wiring diagram. The outdoor unit draws its power from the indoor unit.

WARNING

Be sure to comply with local codes on running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.).

Each wire must be firmly connected.

No wire should be allowed to touch refrigerant tubing, the compressor, or any moving part.

WARNING

To avoid the risk of electric shock, each air conditioner unit must be grounded.

WIRING SYSTEM DIAGRAM

OUTDOOR

 

INDOOR

UNIT

 

(B)

UNIT

Terminal

 

Terminal

Blue

 

N(1)

 

N(1)

 

 

2

Black

 

2

 

 

3

Brown

 

3

 

 

 

Yellow-Green

 

 

 

(Grounding Line)

(A)

 

 

 

 

 

 

L

L

 

 

 

 

Power Supply

N

N

 

Single Phase

 

 

 

 

220-240VAC 50HZ

 

P.C.B

 

Grounding Line

 

Fig. 18 (Cooling Model)

OUTDOOR

 

(B)

INDOOR

UNIT

 

 

UNIT

 

Yellow-Green

 

 

 

 

(Grounding Line)

 

 

N

Blue

 

 

N

 

 

 

2

Black

 

 

2

 

 

 

3

Brown

 

 

3

 

(C)

 

 

Violet

 

 

4

 

 

4

 

 

 

5

Orange

 

 

5

 

 

 

Terminal

 

 

 

Terminal

 

 

 

(A)

 

 

 

L

 

L

 

 

 

 

 

Power Supply

N

 

N

 

Single Phase

 

 

 

 

 

 

220-240VAC 50HZ

 

P.C.B

 

 

 

 

 

 

Grounding Line

 

Fig. 19 (Heat Pump Model)

26

Page 28
Image 28
Haier SAP-K18AM, KC18AGH instruction manual Install Indoor Unit, Installation Service, 9.4.2Wire Length and Diameter