Desa EVDDVF36PN, EVDDVF36STN Installing Log Set, Gas Supply Testing, Installation, Continued

Models: EVDDVF36STN

1 28
Download 28 pages 56.43 Kb
Page 18
Image 18
INSTALLING LOG SET

GAS SUPPLY TESTINGManual backgroundManual backgroundManual background® DIRECT-VENT GAS FIREPLACE

EVDDVF36PN and EVDDVF36STN

INSTALLATION

Continued

Manual background WARNING: All gas piping and connections must be tested for leaks after the installation is completed.

After ensuring that the gas valve is open, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected and corrected.

Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.

Manual background WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier.

GAS RATING

TYPE OF GAS

NATURAL

Max. Input Rating:

30,000 Btu/hr

Orifice Size

 

(0-4,500 Ft.):

7/64"

 

 

Manifold Pressure:

3.5 in. WC

**Minimum Supply

 

Pressure:

4.5 in. WC

**Maximum Supply

 

Pressure:

10.5 in. WC

 

 

** For the purpose of input adjustment.

INSTALLING LOG SET

Before proceeding, make sure the gas con- trol valve is in the “OFF” position. Logs have been packaged separately to prevent damage to glass or refractory.

1.Remove top and bottom louvers by si- multaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from locating holes. Repeat for bottom end spring latches and pull outward. Reverse procedure to install louvers back.

2.Remove the screen rod by sliding spring clip on one end toward the cen- ter. Slide rod into screen rod hole until other end of rod is free. Remove rod.

3.To open the glass door, open the pairs of latches located on the top and bottom of the firebox (see Figure 42). Note: Use caution when opening these latches.

4.Carefully open the door. The glass door is mounted to the firebox with 5 screws.

5.To remove the logs from the shrink wrap, carefully cut the plastic around the perimeter of the log. Do not try to remove the logs from the package with- out first cutting the plastic.

6.Figure 43, page 19 shows the log set. Logs “A” have the knot at the end of the log. Logs “B” have the knot at the middle of the log. Twigs “C” have the shape of a “Y”. Twigs “D” have the shape of bent twigs. Twig “E” is a straight twig which is placed across the top of Logs “B”.

7.Figure 44, page 19, shows the top view of the burner and grate.

8.Place logs “A” as shown in Figure 45, page 19.

9.Place logs “B” as shown in Figure 46, page 19. Lift the end of log “A” that will be propped up and place log “B” under it. At the same time, the other side of log “B” is placed over the other log “A”. Repeat procedure for the other log “B”.

10.Take twigs “C” (shaped like a “Y”) and place them as shown in Figure 47, page 19.

11.Take twigs “D” (bent twig) and place them as shown in Figure 47, page 19.

12.Place twig “E” across the top of logs “B” a shown in Figure 47, page 19.

13.When finished installing the logs, close the glass doors while making certain that the safety door switch is fully depressed by the door frame before securing the four (4) spring loaded latches.

14.Replace the louvers in reverse order with the grilles pointing in the down position.

Manual backgroundManual background Open

Close

Figure 42 - Removing Glass Door

GAS SUPPLY TESTING

Note: This section is intended as a guide for qualified service technicians installing gas to the appliance.

Manual background CAUTION: Do not connect appliance before pressure test- ing gas piping. Damage to the gas valve may result and an un- safe condition may be caused.

The gas control valve is secured underneath the firebox with two brackets fastened to the firebox bottom. Two pressure taps are pro- vided on the gas control valve for a pressure gauge connection (see Figure 41).

Outlet

Inlet

Pressure

Pressure

Tap

Tap

Red Surface Indicates For Propane/LP Use Only

Flexible Gas Line

Do NOT Kink

Note:

1)Wire Connections Not Shown for Clarity

2)* 1/8" NPT Plugged Tapping

Equipment

Shutoff

Valve

1/2" NPT

Incoming

Gas Line

Figure 41 - Connecting Flexible Gas Line to Electronic Valve

18

106573

Page 18
Image 18
Desa Installing Log Set, Gas Supply Testing, DIRECT-VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN, Installation