Desa DIRECT-VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN, Glossary Of Terms

Models: EVDDVF36STN

1 28
Download 28 pages 56.43 Kb
Page 2
Image 2
® DIRECT-VENT GAS FIREPLACE

GLOSSARY OFManual backgroundManual backgroundManual background® DIRECT-VENT GAS FIREPLACE

EVDDVF36PN and EVDDVF36STN

Left Side

TOP VIEW

Alternate

Bottom Gas

Surround

(Left Side)

Supply Inlets

 

Back of

Surround

23 5/8

 

 

 

39 3/4

(60cm)

 

 

(Front)

ø1.5

ø1.5

(101cm)

(Back) 11 15/16

 

(4cm)

(4cm)

 

26 3/8

(30cm)

 

 

 

(67cm)

 

 

 

 

Right Side

(Right Side)

 

 

 

10 1/2

10 1/2

 

3 (8cm)

Surround

(27cm)

(27cm)

 

 

 

BACK VIEW

Manual backgroundManual background 1 (3cm)

34 3/4

(88cm)

225/8

(57cm)

Manual background 3 (8cm) Manual background 2 (5cm)

GLOSSARY OF

TERMS

Chase - A box-like enclosure to protect venting from the elements when the venting run is on the outside of a structure.

Mastic - A pliable sealant for use around the vent terminal.

Snorkel Termination - A box that raises

RIGHT SIDE

Top Spacer

FRONT VIEW

1 1/4 (3cm)

 

 

 

Rating Plate

 

 

Location

30

 

 

(76cm)

22 5/8

 

(Opening)

(57cm)

 

 

32 (81cm) (Opening)

1 7/8 (5cm)

19 7/8 (50cm)

41 1/8 (104cm)

 

(Opening)

 

25 (64cm)

 

 

Figure 1 - EVDDVF36PN (Peninsula) Dimensions

Left Side

TOP VIEW

Alternate

 

BACK VIEW

 

Bottom Gas

 

 

Surround

 

 

 

 

(Left Side)

Supply Inlets

 

 

 

Back of

 

 

 

 

 

 

 

 

 

 

 

Surround

 

 

 

39 3/4

 

 

 

23 5/8

 

 

 

 

 

(60cm)

 

 

(101cm)

 

 

34 3/4

 

 

ø1.5

ø1.5

(Front)

 

 

(Back)

11 15/16

 

 

 

(88cm)

(4cm)

(4cm)

26

3/8

 

 

(30cm)

 

 

 

22 5/8

 

 

 

 

(67cm)

 

(57cm)

 

 

(Right Side)

 

 

 

 

 

Right Side

10 1/2

11 1/8

 

 

 

 

(27cm)

(28cm)

 

 

 

3 (8cm)

Surround

 

 

3 (8cm)

1 (3cm)

 

 

 

 

2 (5cm)

 

 

 

 

 

 

 

 

1 1/4 (3cm)

RIGHT SIDE

 

Top Spacer

 

FRONT VIEW

 

 

 

 

 

 

 

 

 

 

 

 

Rating Plate

 

30

 

 

 

 

Location

 

 

 

 

 

 

 

 

(76cm)

22 5/8

 

 

 

 

 

(Opening)

(57cm)

 

 

 

 

 

 

 

 

32 (81cm) (Opening)

 

1 7/8 (5cm)

 

23 5/8 (60cm)

 

 

 

43 1/8 (110cm)

 

 

 

25 (64cm)

 

Figure 2 - EVDDVF36STN (See Thru) Dimensions

Note: All dimensions in this manual are in inches unless otherwise specified.

the horizontal termination above ground level clearances.

Vent Terminal - Mounted on an outside wall or roof to separate the inlet and outlet of the vent system and protect it from weather.

Vinyl Siding Standoff - A metal box that separates the vent cap from vinyl siding.

Wall Thimble/Firestop - A metal plate used to secure the vent pipe when it passes through a wall or ceiling.

2

106573

Page 2
Image 2
Desa installation manual DIRECT-VENT GAS FIREPLACE EVDDVF36PN and EVDDVF36STN, Glossary Of Terms