DECORATIVE FACING

OWNER’S MANUAL

INSTALLATION

Continued

BURNER FLAME ADJUSTMENTWARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier.

DELECTRODE BC A Manual backgroundManual backgroundManual background

E Manual background A

C

D

B

 

Figure 43 - Log Set (9 Pieces)

 

Left

 

 

 

Left

 

 

D

 

C

 

 

 

Back

 

E

Front

 

 

 

C Manual backgroundManual backgroundManual backgroundManual backgroundManual background D Manual background

Right

Figure 47 - Installing Twigs “C, D, E ” (Top View)

DECORATIVE FACING

Any noncombustible material may be used for facing (glass, tile, brick, etc.) as long as the proper clearances are observed (see Clearances, page 4). IMPORTANT: Lou- vered openings must not be obstructed, and upper and lower panels must remain remov- able for servicing. Use only heat-resistant, noncombustible mortar or adhesive when securing facing material.

Note: Combustible material, such as wood, that has been fireproofed is not considered noncombustible.

Manual background 0.75

Manual background0.34

Figure 49 - Burner and Electrode (Top View)

BURNER FLAME ADJUSTMENT

The air shutter, located at the underside of the main burner (see Figure 50), has been factory preset to the proper air-to-gas ratio which results in an even, clean burning flame across the burner (see Figure 51). If readjustment is necessary, you can restore the proper air-to- gas ratio by loosening the air shutter screw and rotating the air shutter until the proper flame setting is achieved (the shutter's nor- mal setting is “full opened”. Do not forget to retighten the air shutter screws.

Orifice

Burner

Air Shutter

 

Back

Front

Right

Figure 44 - Burner and Grate (Top View)

ELECTRODE

ASSEMBLY

ADJUSTMENT

The electrode assembly is factory preset for

Firebox Bottom

Venturi

Tube

Burner Gas Line

 

Left

Back

Front

Right

Figure 45 - Installing Logs “A” (Top View)

 

 

Left

 

Back

 

A

Front

B

B

 

 

 

 

 

 

 

A

 

Right

Figure 46 - Installing Logs “B ” (Top View)

proper operation. Alteration to these settings may have occurred during shipping and han- dling. If this is the case, some minor adjust- ments may be necessary and should be done by a qualified technician. To access the elec- trode, the glass door must be opened. The proper settings for the electrode height should be at a distance of 5/8" from the top of the burner as shown in Figure 48.

Top of Burner

1/8"

(3mm)

5/8"

(15.8mm)

Port Hole

Figure 48 - Burner and Electrode (Side View)

Figure 50 - Connecting Venturi and Orifice

CORRECT

 

 

Long, Blue Flame

INCORRECT

with Yellow Tips

 

CLOSE

 

SHUTTER

Short, Sharp,

 

Blowing Flame

INCORRECT

 

OPEN

Long, Uneven,

SHUTTER

 

Yellow Flame

Figure 51 - Burner Flame Patterns