® DIRECT-VENT GAS FIREPLACE

EVDDVF36PN and EVDDVF36STN

GENERAL VENTING Continued

N

N

D

E V

B L

 

C

 

 

Fixed

V

 

Closed

 

 

F

Openable

 

V

 

B

Openable Fixed

Closed

H

V

B

I

G

B

B

V J X

G

A

M

V

K X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

 

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum]

B= clearance to window or door that may be opened

[12 inches (305mm) minimum]

C = clearance to permanently closed window [minimum 12 inches (305mm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (610mm) from the center-line of the terminal [18 inches (457mm) minimum]

E= clearance to unventilated soffit [12 inches (305mm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (914mm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (1829mm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (305mm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (1829mm) minimum]

L= † clearance above paved side-walk or a paved driveway located on public property [*84 inches (2133mm) minimum]

M= clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡]

N= clearance above a roof shall extend a minimum of 24 inches (610mm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (457mm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*

*as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow the current National Fuel Gas Code, ANS Z223.1

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

A

 

A = 6" (152mm)

 

V

Outside Corner

V

B B = 6" (152mm)

Recessed Location

D

C

C

E

V

Balcony with No Side Wall

G

V

G = Combustible 24" (610mm) Noncombustible 18" (457mm)

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (610mm)

J = 20" (508mm)

C = Maximum depth of 48" (1219mm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (610mm)

E = Clearance from corner in recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm)

Figure 13 - Minimum Clearances for Vent Terminations

6

106573

Page 6
Image 6
Desa EVDDVF36PN, EVDDVF36STN installation manual General Venting

EVDDVF36PN, EVDDVF36STN specifications

Desa EVDDVF36STN and EVDDVF36PN are innovative and versatile electric heating solutions designed for modern indoor environments. These models stand out in the realm of electric heaters due to their advanced technologies, user-friendly features, and energy-efficient characteristics.

One of the main features of Desa EVDDVF36STN and EVDDVF36PN is their dual fuel capability, allowing users to harness the benefits of both electric and gas heating systems. This versatility ensures that users can maintain optimal comfort levels while minimizing energy costs. The models are equipped with a powerful heating element that can efficiently manage large spaces, making them ideal for homes, workshops, or commercial applications.

In terms of technology, both the EVDDVF36STN and EVDDVF36PN are engineered with a high-efficiency heating system that utilizes radiant heat to warm rooms quickly. This technology reduces the time required to reach desired temperatures, ensuring prompt comfort for users. Additionally, the heaters incorporate digital control systems that allow for precise temperature adjustments, enabling users to tailor their heating experience to meet specific preferences.

Another significant characteristic of these models is their sleek and modern design, which blends seamlessly into various interior styles. The cabinets are constructed from durable materials, ensuring longevity and resilience against wear and tear. Both models come with a variety of finishes and colors, allowing users to choose an aesthetic that complements their space.

The Desa EVDDVF36STN and EVDDVF36PN are also equipped with safety features that prioritize user well-being. These include automatic shut-off sensors that activate in case of overheating or if the unit tips over, providing peace of mind to users.

Moreover, these electric heaters are designed with energy efficiency in mind. They have a lower carbon footprint compared to traditional heating systems, contributing positively to environmental conservation efforts. Their efficient operation not only reduces energy consumption but also translates to lower utility bills, making them an economical choice for consumers.

In conclusion, the Desa EVDDVF36STN and EVDDVF36PN electric heaters embody the perfect combination of functionality, technology, safety, and style. Their dual fuel capability, rapid heating technology, and energy efficiency make them an outstanding option for anyone looking to enhance their indoor comfort while being mindful of their environmental impact.