TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

company

 

2.

Burner porting or orifice clogged

2.

Clean burner or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Fireplace produces a whistling noise when

1.

Air in gas line

1.

Operate burner until air is removed from

burner is lit

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP gas company

 

2.

Dirty or partially clogged burner orifice

2.

Clean burner or replace burner orifice

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set so that the flame does

 

 

 

 

not excessively impinge on it

 

2.

Debris around burner air mixer

2.

Inspect the opening at the base of the

 

 

 

 

burner to see that it is NOT packed with

 

 

 

 

any type of material

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common. If noise is excessive, contact qualified service person