Section 4 — Maintenance
Guardian
4. Install the dipstick. | Figure 4.4 – Oil Drain Hose and Filter |
5.Reset the AUTO/OFF/MANUAL switch to its origi- nal position.
Figure 4.3 — Oil Dipstick and Fill,
12 kW and 15 kW
Oil Dipstick
Oil Fill
4.3CHANGING THE ENGINE OIL
4.3.1 ENGINE OIL RECOMMENDATIONS
Use oil of American Petroleum Institute (API) Service Class SG, SH or SJ. Use all season SAE
NOTE:
The unit is supplied with
Any attempt to crank or start the engine before
!it has been properly serviced with the recom- mended oil may result in an engine failure.
4.3.2 OIL CHANGE PROCEDURE
To change the oil, proceed as follows:
1.Run the engine until it is thoroughly warmed up then shut OFF the engine.
2.Immediately after the engine shuts OFF, pull the oil drain hose (Figure 4.4) free of its retaining clip. Remove the cap from the hose and drain the oil into a suitable container.
3.After the oil has drained, replace the cap onto the end of the oil drain hose. Retain the hose in the clip.
4.Refill with the proper recommended oil (see Section 4.3.1). See Section 1.5.2 for oil capaci- ties.
Loosen
OilDrain
Hose
Oil Filter
4.4CHANGING THE OIL FILTER
Change the engine oil filter as follows:
1.With the oil drained, remove the old oil filter by turning it counterclockwise.
2.Apply a light coating of clean engine oil to the gas- ket of the new filter. See Section 1.5.1 for recom- mended filter.
3.Screw the new filter on by hand until its gasket lightly contacts the oil filter adapter. Then, tighten the filter an additional 3/4 to one turn (Figure 4.4).
4.Refill with the proper recommended oil (see Section 4.3.1). See Section 1.5.2 for oil capaci- ties.
5.Start the engine and check for leaks.
4.5CHANGING THE ENGINE AIR CLEANER
4.5.1 7 KW, 12 KW AND 15 KW GENERATORS
See Figures 1.1 and 1.2, for the location of the air cleaner. Use the following procedure (Figure 4.6):
1.Turn the two screws counterclockwise to loosen.
2.Remove the cover and air filter.
3.Wipe away dust or debris from inside of the air box and around edges.
4.Install the new air cleaner into the air box.
5.Install the cover. Turn the two cover screws clock- wise to tighten.
See the “Service Schedule,” Section 4.13 for air cleaner maintenance. See Section 1.5.1 for air filter replacement part number.
18 Generac® Power Systems, Inc.