1 PROGRAMMING LIMITS & FORCE

(Continuing from Installation Poster if provided)

SETTING & TESTING LIMITS AND FORCE

The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making adjustments using the panel located on the bottom of the powerhead. Begin with Step 1 and continue through Step 10. Door Force is set during the final Open/Close cycle of these steps. The powerhead will automatically set door speed at slow if the distance between limits is less than 6 feet. Once Limits and Force are set DO NOT use the or buttons to open or close door.

FOR A LIMITS PROGRAMMING QUICK REFERENCE CARD VISIT WWW.GENIECOMPANY.COM

WARNING

• Make sure doorway is in view and clear of obstacles

and people to avoid injury or damage to property.

• DO NOT operate this unit from wall console before

LIMITS and FORCE are set. Severe damage to the

opener can occur.

• Shuttle MUST be engaged to carriage BEFORE setting

limits. See Installation Poster (if provided) or refer to

Genie

A) CLOSE DOOR TRAVEL LIMIT

pages 11 and 19.

Company

NOTE: If shuttle has NOT been engaged to the carriage, do so now.

Please note that there is a 30 second timeout between each programming step.

A programming timeout during these steps has occured when two RED flashing LEDs appear.

In the event of a timeout please restart at Step 1.

1PRESS and HOLD

PROGRAM

SET

+

 

 

 

 

 

SEE BOTH Blue LEDs come ON

2

RELEASE

SEE round

Blue LED come ON

3PRESS and RELEASE

PROGRAM

+

 

 

 

SEE long Blue

LED come ON

If RED LED comes ON - STOP and

exit programming.

3a

NOTE: If one or both LEDs come ON RED

12/2010

at this time, Limits programming menu

was not entered properly. You must exit

 

programming and restart.

 

To exit the programming function wait 30

 

seconds for the programming to time out.

 

 

4

PRESS and

PROGRAM

SET

 

 

 

RELEASE

 

 

 

SEE round Blue

LED flashing

5 PRESS and HOLD until door is FULLY CLOSED then RELEASE

RAM

 

 

 

 

 

 

 

 

 

 

 

 

G

SET

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTICE

 

 

 

 

 

 

 

 

 

 

Watch door move

NOTE: You can start and stop door movement using either buttons until door is in correct open or closed position.