Genie 3064H manual Test, Adjustment

Models: 3064H 3064

1 27
Download 27 pages 39.21 Kb
Page 8
Image 8

8

 

CONTACT REVERSE TEST

 

 

 

 

 

The Force and Limit settings on the previous page MUST be COMPLETED before Contact

 

Reverse testing.

 

1.Test.

 

 

• Open garage door using wall console.

©2010

 

– Place a 2" x 4" board (laid flat) under center of garage door opening.

 

• Close garage door using wall console.

The

 

• When door contacts board, the door must stop (within 2 seconds) and reverse direction

 

returning to open position.

Genie

2. Adjustment.

Company

 

• If the door:

 

– Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set

 

 

down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

 

 

– Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to

 

 

the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

 

 

• Test again. Repeat as necessary until door reverses upon contacting board.

PRESS and RELEASE

2

3

12/2010

DOOR OPENS

WARNING

A moving door can cause serious injury or death.

1.Keep people clear of opening while door is moving.

2.Do NOT allow children to play with opener, including wall console, remote, or wireless keypad.

3.During programming, door opener could begin to run, so stay away from moving door and its parts.

On Wall Console

1PRESS and RELEASE

4

Once the Contact Reverse Testing is complete continue with Programming Remotes on the next page.

Page 8
Image 8
Genie 3064H manual Test, Adjustment