OPERATION/DIAGNOSTICS

For Compass Units with the SHARK Controller

Flash codes indicate the nature of an abnormal condition directly from the SHARK Information Gauge. Without the use of any servicing tools, the condition can be simply diagnosed.

 

Flash

 

 

Description

 

 

Recommended Action

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

User Fault

 

Possible stall timeout or user error. Release

 

 

 

the joystick to neutral and try again.

 

 

 

 

 

 

 

2

 

 

Battery Fault

 

Check the batteries and cabling. Try charging

 

 

 

the batteries. Batteries may require replacing.

 

 

 

 

 

 

 

3

 

 

Right Motor Fault

 

Check the right motor, connections and

 

 

 

cabling.

 

 

 

 

 

 

 

4

 

 

Left motor fault

 

Check the left motor, connections and

 

 

 

cabling.

 

 

 

 

 

 

 

5

 

 

Right park brake fault

 

Check the right park brake, connections and

 

 

 

cabling.

 

 

 

 

 

 

 

6

 

 

Left park brake fault

 

Check the left park brake, connections and

 

 

 

cabling.

 

 

 

 

 

 

 

7

 

 

SHARK Control Unit Fault

 

Check the SHARK Communications Bus con-

 

 

 

nections and wiring. Replace the Control Unit

 

 

 

 

 

 

 

8

 

 

SHARK Power Module

 

Check SHARK connections and wiring.

 

 

Fault

 

Replace the Power Module.

 

 

 

 

 

9

 

 

SHARK Communications

 

Check SHARK connections and wiring.

 

 

Fault

 

Replace the SHARK Control Unit.

 

 

 

 

 

10

 

 

Unknown Fault

 

Check all connections and wiring. Consult a

 

 

 

service agent.

 

 

 

 

 

 

 

The SHARK modules are not user serviceable. Do not attempt to repair Shark modules.

Note that joystick OONAPU (Out Of Neutral At Power Up) is not a fault. Simply by removing your hand from the joystick and allowing it to return to the neutral position, the fault will immediately clear. If the condition persists after removing your hand, the joystick may be damaged. Consult a Service agent.

26

Page 27
Image 27
Golden Technologies GP600 SS Operation/Diagnostics, For Compass Units with the SHARK Controller, Flash, Description, Code