Goodman Mfg R-410A manual Servicing, Required Liquid Line Temperature

Models: R-410A

1 47
Download 47 pages 31.4 Kb
Page 40
Image 40
REQUIRED LIQUID LINE TEMPERATURE

SERVICING

REQUIRED LIQUID LINE TEMPERATURE

 

 

 

 

 

 

 

 

 

LIQUID PRESSURE

 

REQUIRED SUBCOOLING TEMPERATURE (°F)

 

AT SERVICE VALVE (PSIG)

8

 

10

12

14

16

 

18

189

58

 

56

54

52

50

 

48

195

60

 

58

56

54

52

 

50

202

62

 

60

58

56

54

 

52

208

64

 

62

60

58

56

 

54

215

66

 

64

62

60

58

 

56

222

68

 

66

64

62

60

 

58

229

70

 

68

66

64

62

 

60

236

72

 

70

68

66

64

 

62

243

74

 

72

70

68

66

 

64

251

76

 

74

72

70

68

 

66

259

78

 

76

74

72

70

 

68

266

80

 

78

76

74

72

 

70

274

82

 

80

78

76

74

 

72

283

84

 

82

80

78

76

 

74

291

86

 

84

82

80

78

 

76

299

88

 

86

84

82

80

 

78

308

90

 

88

86

84

82

 

80

317

92

 

90

88

86

84

 

82

326

94

 

92

90

88

86

 

84

335

96

 

94

92

90

88

 

86

345

98

 

96

94

92

90

 

88

354

100

 

98

96

94

92

 

90

364

102

 

100

98

96

94

 

92

374

104

 

102

100

98

96

 

94

384

106

 

104

102

100

98

 

96

395

108

 

106

104

102

100

 

98

406

110

 

108

106

104

102

 

100

416

112

 

110

108

106

104

 

102

427

114

 

112

110

108

106

 

104

439

116

 

114

112

110

108

 

106

450

118

 

116

114

112

110

 

108

462

120

 

118

116

114

112

 

110

474

122

 

120

118

116

114

 

112

486

124

 

122

120

118

116

 

114

499

126

 

124

122

120

118

 

116

511

128

 

126

124

122

120

 

118

40

Page 40
Image 40
Goodman Mfg R-410A manual Servicing, Required Liquid Line Temperature