Goodman Mfg VC8 Operational Checks & Safety Circuit Description, Normal Sequence Of Operation

Models: VC8

1 48
Download 48 pages 50.02 Kb
Page 34
Image 34
OPERATIONAL CHECKS & SAFETY CIRCUIT DESCRIPTION

OPERATIONAL CHECKS & SAFETY CIRCUIT DESCRIPTION

LED

LED

Indication

Possible Causes

Corrective Action(s)

Notes & Cautions

 

Status

 

 

 

 

 

Off

ξ Normal condition

ξ None

ξ None

ξ None

 

1 Flash

ξ Communications

ξ Communications

ξ Depress Learn Button

ξ Depress once

 

 

Failure

Failure

ξ Verify that bus BIAS

quickly for a power-

Red

 

 

 

and TERM

up reset

 

 

 

dipswitches are in the

ξ Depress and hold

Communications

 

 

 

 

 

 

ON position.

for 2 seconds for

LED

 

 

 

 

 

 

 

an out-of-box reset

 

 

 

 

 

 

2 Flashes

ξ Out-of-box reset

ξ Control power up

ξ None

ξ None

 

 

 

ξ Learn button

 

 

 

 

 

depressed

 

 

 

Off

ξ No power

ξ No power to furnace

ξ Check fuses and

ξ Turn power OFF

 

 

ξ Communications

ξ Open fuse

circuit breakers;

prior to repair

 

 

error

ξ Communications error

replace/reset

 

 

 

 

 

ξ Replace blown fuse

 

 

 

 

 

ξ Check for shorts in

 

 

 

 

 

low voltage wiring in

 

 

 

 

 

furnace/system

 

 

 

 

 

ξ Reset network by

 

 

 

 

 

depressing learn

 

 

 

 

 

button

 

 

 

 

 

ξ Check data 1/ data 2

 

 

 

 

 

voltages

 

 

1 Steady

ξ No network found

ξ Broken/ disconnected

ξ Check

ξ Turn power OFF

 

Flash

 

data wire(s)

communications

prior to repair

 

 

 

ξ Furnace is installed as

wiring (data 1/ data 2

ξ Verify wires at

 

 

 

a legacy/ traditional

wires)

terminal blocks are

 

 

 

system

ξ Check wire

securely twisted

Green Receive

 

 

 

connections at

together prior to

 

 

 

terminal block

inserting into

LED

 

 

 

ξ Verify furnace

terminal block

 

 

 

 

installation type

ξ Verify data1 and

 

 

 

 

(legacy/ traditional or

data voltages as

 

 

 

 

communicating)

described above

 

 

 

 

ξ Check data 1/ data 2

 

 

 

 

 

voltages

 

 

Rapid

ξ Normal network

ξ Control is “talking” on

ξ None

ξ None

 

Flashing

traffic

network as expected

 

 

 

On Solid

ξ Data 1/ Data 2

ξ Data 1 and data 2

ξ Check

ξ Turn power OFF

 

 

miss-wire

wires reversed at

communications

prior to repair

 

 

 

furnace, thermostat,

wiring (data 1/ data 2

ξ Verify wires at

 

 

 

or CT™ compatible

wires)

terminal blocks are

 

 

 

outdoor AC/HP

ξ Check wire

securely twisted

 

 

 

ξ Short between data 1

connections at

together prior to

 

 

 

and data 2 wires

terminal block

inserting into

 

 

 

ξ Short between data 1

ξ Check data 1/ data 2

terminal block

 

 

 

or data 2 wires and R

voltages

ξ Verify data1 and

 

 

 

(24VAC) or C (24VAC

 

data voltages as

 

 

 

common)

 

described above

NORMAL SEQUENCE OF OPERATION

POWER UP

The normal power up sequence is as follows:

115 VAC power applied to furnace.

Integrated control module performs internal checks.

Integrated control module displays 88 on dual 7-segment display LED’s.

Integrated control module monitors safety circuits continuously.

Furnace awaits call from thermostat. Dual 7-segment LED’s display 0 P while awaiting call from thermostat.

HEATING MODE

The normal operational sequence in heating mode is as fol- lows:

R and W1 (or R and W1/W2) thermostat contacts close, initiating a call for heat.

Integrated control module performs safety circuit checks.

Induced draft blower is energized on high speed for a 15- second prepurge. Humidifier terminal is energized with induced draft blower.

Induced draft blower steps to low speed following prepurge. Low stage pressure switch contacts are closed.

Igniter warm up begins upon step to low speed and presence of closed low stage pressure switch contacts.

34

Page 34
Image 34
Goodman Mfg VC8 instruction manual Operational Checks & Safety Circuit Description, Normal Sequence Of Operation