Graco 247936, 247937 Connect the Air Line, Connect the Charging Probe, Grounded Air Supply Hose

Models: 247936 247937

1 44
Download 44 pages 32.37 Kb
Page 11
Image 11

Connect the Air Line

To reduce the risk of electric shock or other serious injury, the air supply hose must be electrically con- nected to a true earth ground. Use only Graco

Grounded Air Supply Hose.

1.Connect the Graco Grounded Air Supply Hose (R) between the air supply line and the gun's air inlet (V) (FIG. 2). The gun air inlet fitting has a left-hand thread. Connect the air supply hose ground wire (Q) to a true earth ground.

V

Q

To air supply

R

ti1259ati1259

FIG. 2

2.Install an air line filter/water separator (O) on the gun air line to ensure a dry, clean air supply to the gun. Dirt and moisture can ruin the appearance of your finished workpiece and can cause the gun to malfunction.

3.Install a bleed-type air regulator (G) on the pump and gun air supply lines to control air pressure to the pump and gun.

4.Install a bleed-type air valve (E) on the pump air line to shut off air to the pump. Install an additional bleed-type air valve (C) on the main air line (A) to isolate the accessories for servicing.

The bleed-type air valve (E) is required in your sys- tem to relieve air trapped between the valve and the pump after the air regulator is shut off. Trapped air can cause the pump to cycle unexpectedly, which can result in serious injury, including splashing fluid in the eyes or on the skin.

Installation

5.Install an air shutoff valve (P) on each gun air supply line to shut off air to the gun(s).

Connect the Charging Probe

1. Apply dielectric grease to probe socket.

Probe

Socket

ti12722

FIG. 3

2.Press electrode on in Connect/Disconnect position shown in FIG. 4.

3.Rotate electrode to spray position.

 

Connect the Charging Electrode

Connect/Disconnect

Spray

Position

Position

 

 

 

ti1933a

FIG. 4

NOTICE

The external charging probe rotates easily. Do not press too hard when rotating it or it could be dam- aged.

NOTICE

For proper performance, do not operate electro- statics if the charging probe is not in spray position.

312900G

11

Page 11
Image 11
Graco 247936, 247937 Connect the Air Line, Connect the Charging Probe, Grounded Air Supply Hose