Before performing any troubleshooting procedure:

1.Perform Pressure Relief Procedure In the Exact- aBlend AGP Advanced Glazing Proportioner, Setup-Operation manual.

2.Turn off main disconnect at the machine.

3.Allow equipment to cool.

Try the recommended solutions in the order given for each problem, to avoid unnecessary repairs. Also, determine that all circuit breakers, switches, and con- trols are properly set and wiring is correct before assum- ing there is a problem.

Common Problems

Problem

Cause

Verification

Solution

 

 

 

 

 

 

 

 

Heating is slow.

Low power.

Measure voltage across cir-

1. If voltage is lower than

 

 

cuit breakers. Voltage

expected, use electrical

 

 

should measure between

schematic to locate

 

 

190 and 264 Vac.

faulty wiring or connec-

 

 

 

tion.

 

 

 

2. Have a qualified electri-

 

 

 

cian service electrical

 

 

 

components.

 

 

 

 

Heating over shoots.

Defective solid state relay.

Verify for given zone that

Verify RTD wire or heater

 

 

temperature does not

power cord is attached to

 

 

increase when zone is dis-

correct heat module.

 

 

abled.

 

 

 

Replace relay.

 

 

 

 

 

 

 