Graco 24R200 operation manual Platen Maintenance, Remove Platen Covers and Heaters

Models: 24R200

1 28
Download 28 pages 39.66 Kb
Page 15
Image 15
Maintenance

Maintenance

Maintenance

Platen Maintenance

Remove and Reinstall Platen Wipers

Refer to Supply Units Repair-Partsmanual for instruc- tions.

If the platen does not come out of the pail easily when the pump is being raised, the air assist tube or check valve may be plugged. A plugged valve prevents air from reaching the underside of the plate to assist in raising it from the pail.

1.Turn off main disconnect at the machine.

2.Allow equipment to cool.

3.Relieve pressure and disassemble air assist valve. Refer to Supply Systems Repair-Parts manual.

4.Clear air assist tube in platen. Clean all parts of valve and reassemble. Refer to Supply Systems Repair-Parts manual.

5.Remove bleed stick from platen. Push bleed stick through bleed relieve port (P) to remove material residue. See FIG. 3.

6.Remove platen covers. See FIG. 3.

a.Remove platen cover fasteners (F).

b.Remove both platen covers (C) and ground wire from platen.

7.Remove any excess fluid. Use a soft wire brush on heater coils (H). See FIG. 3.

8.Inspect platen heater blocks (B) or heater (H) for burn or melt spots. Replace platen heater if neces- sary. See FIG. 3.

9.Check for loose connections and damaged wires.

10.Follow steps in reverse order to reassemble platen.

NOTE: Torque platen cover fasteners (F) to 60 +/- 10 in-lbs (6.8 +/- 1.1 N•m) for 55 gallon platen.

 

F

 

C

Bleed

B

 

Stick

H

 

P

FIG. 3: Remove Platen Covers and Heaters

332511A

15

Page 15
Image 15
Graco 24R200 operation manual Platen Maintenance, Remove Platen Covers and Heaters