Troubleshooting

Problem

Cause

Verification

Solution

 

 

 

 

 

 

 

 

No heat.

Tripped circuit breaker.

Visually check circuit

Determine cause of tripped

 

 

breaker for a tripped condi-

circuit breaker. Then repair

 

 

tion.

fault and reset main circuit

 

 

 

breaker.

 

 

 

 

 

Low power.

Measure voltage across cir-

1. If voltage is lower than

 

 

cuit breakers. Voltage

expected, use electrical

 

 

should measure between

schematic to locate

 

 

190 and 264 Vac.

faulty wiring or connec-

 

 

 

tion.

 

 

 

2. Have a qualified electri-

 

 

 

cian service electrical

 

 

 

components.

 

 

 

 

 

Cable unplugged/loose

Check for loose or discon-

Attach plug/wire.

 

wire.

nected wires and plugs.

 

 

 

 

 

 

Incorrect temperature set

Verify zone has a correct

Enter Setup and enter cor-

 

point.

temperature setting on the

rect temperature.

 

 

controller.

 

 

 

 

 

 

Contactor not closing.

Turn on heat for zone A1

1. Verify that there are no

 

 

and ensure contactor

other error conditions

 

 

closes.

that would prevent

 

 

 

heater from starting.

 

 

 

2. Replace contactor.

 

 

 

 

332511A

17

Page 17
Image 17
Graco 24R200 operation manual Problem Cause Verification Solution