Repair

Repair

Replace Platen Heaters and Sensor

55 Gallon Platen Heater and Sensor

1.Turn off main disconnect at the machine.

2.Allow equipment to cool.

3.Remove both platen cover fasteners (F).

4.Remove both platen covers (C) and ground wire from platen.

F

C

N

B

 

L

 

W

 

R

FIG. 4: Replace Platen Heaters and RTD sensor (R)

5.Remove platen heater blocks (B).

a.Use a hex wrench to remove three nuts (N) and washers (L, W) from each heater block.

b.Remove screws from junction box cover. Loosen strain relief nut, and remove junction box cover.

c.Disconnect four platen heater wires (labeled A and B) and RTD sensor (R) connector in the ter- minal box.

d.Remove screws and washers. Remove platen heater blocks (B) and RTD sensor (R).

6.Install new platen heaters and RTD sensor (R). Secure RTD sensor (R) with screw and washer. Secure platen heater blocks with nuts and washers.

7.Label platen heater wires A and B. Reroute platen heater wires and platen RTD sensor (R) through the conduit to the junction box. Reconnect the four wires to the appropriate terminal block A and B. Recon- nect the platen RTD sensor (R).

8.Reinstall junction box cover. Secure with screws and tighten strain relief nut.

9.Reconnect ground wire, and install platen covers. Secure platen covers with fasteners. Torque platen cover fasteners to 60 in-lbs +/- 10 in-lbs (6.8 +/- 1.1 N•m).

18

332511A

Page 18
Image 18
Graco 24R200 operation manual Repair, Replace Platen Heaters and Sensor