B.Maintenance Tasks-Qualified Service
Technician
To prevent inadvertent burner operation while servicing this appliance:
•Unplug DC regulator from junction box.
•Remove batteries from battery pack (if installed).
•Shut off gas supply to the appliance.
The following tasks must be performed by a qualified ser- vice technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, drop cloth and a stable work surface.
•Inspect gasket seal and its condition.
•Inspect fixed glass assembly for scratches and nicks that can lead to breakage when exposed to heat.
•Confirm there is no damage to glass or glass frame. Replace as necessary.
•Verify that fixed glass assembly is properly retained and attachment components are intact and not damaged. Replace as necessary.
Logs
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves.
•Inspect for damaged or missing logs. Replace as neces- sary. Refer to Section 14.E for log placement instructions.
•Verify correct log placement and no flame impingement causing sooting. Correct as necessary.
Firebox
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, sandpaper, steel wool, cloths, mineral spirits, primer and
•Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary.
•Replace fireplace if firebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust cloths
•Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.
•Remove all foreign objects.
•Verify unobstructed air circulation.
Gas Pressure Information
Frequency: Upon initial installation and gas valve re- placement or service.
By: Qualified Service Technician
Tools needed: Protective gloves, manometer, flashlight, screw driver set.
•Gas pressure taps are accessible by removing the deco- rative front and fixed glass assembly. Refer to section 11.A for information related to the gas valve and gas pressure settings.