Heat & Glo LifeStyle 2197-980 Top Vent - Horizontal Termination One Elbow, H1 V1, Two Elbows

Models: 2197-980

1 71
Download 71 pages 10.26 Kb
Page 26
Image 26
Top Vent - Horizontal Termination

Top Vent - Horizontal Termination

One Elbow

Note: A 6 in. (152 mm) section of straight flue must be at- tached to the fireplace before a 90° elbow.

H1

V1

Figure 7.3

V1 Minimum

H1 Maximum

Elbow only

2 ft.

610 mm

1 ft.

305 mm

2-1/2 ft.

762 mm

2 ft.

610 mm

5-1/2 ft.

1.68 m

 

 

 

 

3 ft.

914 mm

9 ft.

2.74 m

 

 

 

 

4 ft.

1.22 m

12 ft.

3,66 m

5 ft.

1.52 m

15 ft.

4.57 m

V1 + H1 Maximum = 38 ft. (11.58 m)

H1 Maximum = 15 ft. (4.57 m)

Two Elbows

Note: A 6 in. (152 mm) section of straight flue must be attached to the fireplace before a 90° elbow.

V1 Minimum

H1 + H2 Maximum

Elbow only

Not Allowed

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

5 ft.

1.52 m

 

 

 

 

3 ft.

914 mm

8 ft.

2.44 m

 

 

 

 

4 ft.

122 mm

11 ft.

3.35 m

5 ft.

152 mm

14 ft.

4.27 m

V1 + H1 + H2 Maximum = 38 ft. (11.58 m)

H1 + H2 Maximum = 14 ft. (4.27 m)

H2

H1

V1

INSTALLED

HORIZONTALLY

Figure 7.4

26

Heat & Glo • SOHO-N-AUB2197-980 Rev. F • 5/12

Page 26
Image 26
Heat & Glo LifeStyle 2197-980 Top Vent - Horizontal Termination One Elbow, H1 V1, Two Elbows, V1 Minimum, H1 Maximum