Heat & Glo LifeStyle 2197-980 Top Vent - Vertical Termination, Straight Up Vertical Flue System

Models: 2197-980

1 71
Download 71 pages 10.26 Kb
Page 28
Image 28
Top Vent - Vertical Termination

Top Vent - Vertical Termination

MODEL

FLUE TERMINATION APPROVALS

SOHO-N-AUB

SLP-TVHW

This model is approved to use SLP Series flue pipe com- ponents. A SLP-TVHWvertical Termination Cap must be used to terminate flue systems in a vertical position.

Approved flue system components are labeled for identifi- cation. NO OTHER FLUE SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are in- cluded with each flue termination kit and should be used in conjunction with this manual.

WARNING! Risk of Fire! This gas appliance and flue assembly must be flued directly to the outside and must never be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate flue system-common flue systems are prohibited.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping material could ignite and will in- terfere with proper operation of doors and louvers.

Horizontal sections 3 inches (76.2 mm) from the top of the pipe.

Horizontal sections 2-1/2 inches (63.5 mm) at wall shield firestops.

Horizontal sections 1 inches (25.4 mm) from sides and bottom of the pipe.

Vertical sections 1 inches (25.4 mm) on all sides of pipe.

Failure to keep insulation or other material away from vent pipe may cause over heating and fire.

For alternative installations, other than depicted, contact your dealer for further information.

Straight Up Vertical Flue System

Figure 7.6 shows straight up vertical flue system approved for use on this model.

If the fireplace installation requires a vertical flue exceeding 14-3/4 ft (4.5 m) above the unit with no horizontal flue or elbows a vertical flue restrictor must be installed (see Figure 7.7).

CAP Straight Up Vertical Flue System

V

MAX. RUN

38 FT.

(11.58 m)

V1

Figure 7.6

28

Heat & Glo • SOHO-N-AUB2197-980 Rev. F • 5/12

Page 28
Image 28
Heat & Glo LifeStyle 2197-980 owner manual Top Vent - Vertical Termination, Straight Up Vertical Flue System, V Max. Run