5 Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.
NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.
NOTE: For actual appliance dimensions refer to Sec- tion 16.
A
13mm
A
B
C
TOP VENT,
ONE 90º ELBOW
B
ALCOVE
INSTALLATION
D
MINIMUM
| A | B | C | D |
Inches | 33 | 29 | 47 | 35 |
|
|
|
|
|
Millimeters | 841 | 740 | 1187 | 892 |
In addition to these framing dimensions, also reference the following sections:
•Clearances and Mantel Projections (Sections 5.D and 13.B).
•Flue Clearances and Framing (Section 6).
Figure 5.1 Appliance Locations
20 | Heat & Glo • |