FLUE TERMINATION APPROVALS

SLP-TRAP2 HORIZONTAL TERMINATION CAP SLP-TVHW VERTICAL TERMINATION CAP DVP-FBHT HORIZONTAL TERMINATION CAP

Flue System Approvals And Installations

These models have flue starting collars on both the top and the back of the unit. Depending upon the installation, decide which ONE set of starting collars will be used to at- tach the flue system. The starting collar sealing cap must remain on the starting collar NOT used.

These models use SLP series direct flue components.

Approved flue system components are labeled for identi- fication. NO OTHER FLUEING SYSTEMS OR COMPO- NENTS MAY BE USED. Detailed installation instructions are included with each flue termination kit and should be used in conjunction with this manual. Figure 7.8 shows flue system components and terminations.

Identifying Flue Components

The flue systems installed on this gas fireplace may include one, two, or three 90° elbow assemblies. The relationships of vertical rise to horizontal run in flue configurations using 90° elbows MUST BE strictly adhered to. The rise to run relationships are shown in the flueing drawings and tables on the next few pages.

WARNING! Risk of Fire! This gas appliance and flue as-

sembly must flue directly to the outside and must never be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a sepa- rate flue system-common flue systems are prohibited.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping material could ignite and will in- terfere with proper operation of doors and louvers.

Horizontal sections 3 in. (76 mm) from the top of the pipe.

Horizontal sections 2-1/2 in. (64 mm) at wall shield firestops.

Horizontal sections 1 in. (25 mm) from sides and bottom of the pipe.

Vertical sections 1 in. (25 mm) on all sides of pipe.

Failure to keep insulation or other material away from vent pipe may cause over heating and fire.

For alternative installations, other than depicted, contact your dealer for further information.

 

VERTICAL

STORM COLLAR

 

TERMINATION

 

 

 

HORIZONTAL

 

ROOF FLASHING

 

TERMINATION

 

 

 

 

 

HORIZONTAL PIPE

 

 

 

SUPPORT

 

 

 

PIPE LENGTH

WALL FIRESTOP

 

 

 

90 DEGREE

 

 

ELBOW

CEILING

WALL BRACKET

 

 

 

 

FIRESTOP

 

Flue system termination kits

 

 

SLP SERIES

 

 

SLP-TRAP2

SLP-TVHW

DVP-FBHT

 

Figure 7.8 Flue Components and Terminations

 

 