Technical Data
Fluid Temperature Range
NOTICE
Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid temperature range. Stay within the temperature range of the 
| 
 | 
 | Fluid Temperature Range | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | Polypropylene or | |
| 
 | Aluminum or | 
 | Conductive Polypropylene | ||
| 
 | Stainless Steel Pumps | 
 | Pumps | ||
| Diaphragm/Ball/Seat Material | 
 | 
 | 
 | 
 | 
 | 
| Fahrenheit | Celsius | 
 | Fahrenheit | Celsius | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Acetal (AC) | 10° to 180°F | 
 | 32° to 180°F | 0° to 82°C | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 10° to 180°F | 
 | 32° to 180°F | 0° to 82°C | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| FKM Fluoroelastomer (FK)* | 
 | 32° to 180°F | 0° to 82°C | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Geolast® (GE) | 
 | 32° to 150°F | 0° to 66°C | ||
| Neoprene overmolded diaphragm (CO) | 0° to 180°F | 
 | 32° to 180°F | 0° to 82°C | |
| or Neoprene check balls (CR or CW) | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Polypropylene (PP) | 32° to 180°F | 0° to 82°C | 
 | 32° to 180°F | 0° to 82°C | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| PTFE overmolded diaphragm (PO) | 40° to 180°F | 4.0° to 82°C | 
 | 40° to 180°F | 4° to 82°C | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| PTFE check balls or  | 40° to 220°F | 4° to 104°C | 
 | 40° to 180°F | 4° to 82°C | 
| PTFE/EPDM diaphragm (PT) | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| PVDF (PV) | 10° to 225°F | 
 | 32° to 180°F | 0° to 82°C | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Santoprene® (SP) | 
 | 32° to 180°F | 0° to 82°C | ||
| TPE (TP) | 
 | 32° to 150°F | 0° to 66°C | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
*The maximum temperature listed is based on the ATEX standard for T4 temperature classification. If you are operating in a 
| 312877C | 23 | 