Fluid Temperature Range

Technical Data

Fluid Temperature Range

NOTICE

Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid temperature range. Stay within the temperature range of the most-restricted wetted component. Operating at a fluid temperature that is too high or too low for the components of your pump may cause equipment damage.

 

 

Fluid Temperature Range

 

 

 

 

 

 

 

 

 

 

 

Polypropylene or

 

Aluminum or

 

Conductive Polypropylene

 

Stainless Steel Pumps

 

Pumps

Diaphragm/Ball/Seat Material

 

 

 

 

 

Fahrenheit

Celsius

 

Fahrenheit

Celsius

 

 

 

 

 

 

Acetal (AC)

10° to 180°F

-12° to 82°C

 

32° to 180°F

0° to 82°C

 

 

 

 

 

 

Buna-N (BN)

10° to 180°F

-12° to 82°C

 

32° to 180°F

0° to 82°C

 

 

 

 

 

 

FKM Fluoroelastomer (FK)*

-40° to 275°F

-40° to 135°C

 

32° to 180°F

0° to 82°C

 

 

 

 

 

 

Geolast® (GE)

-40° to 150°F

-40° to 66°C

 

32° to 150°F

0° to 66°C

Neoprene overmolded diaphragm (CO)

0° to 180°F

-18° to 82°C

 

32° to 180°F

0° to 82°C

or Neoprene check balls (CR or CW)

 

 

 

 

 

 

 

 

 

 

 

Polypropylene (PP)

32° to 180°F

0° to 82°C

 

32° to 180°F

0° to 82°C

 

 

 

 

 

 

PTFE overmolded diaphragm (PO)

40° to 180°F

4.0° to 82°C

 

40° to 180°F

4° to 82°C

 

 

 

 

 

 

PTFE check balls or two-piece

40° to 220°F

4° to 104°C

 

40° to 180°F

4° to 82°C

PTFE/EPDM diaphragm (PT)

 

 

 

 

 

 

 

 

 

 

 

PVDF (PV)

10° to 225°F

-12° to 107°C

 

32° to 180°F

0° to 82°C

 

 

 

 

 

 

Santoprene® (SP)

-40° to 180°F

-40° to 82°C

 

32° to 180°F

0° to 82°C

TPE (TP)

-20° to 150°F

-29° to 66°C

 

32° to 150°F

0° to 66°C

 

 

 

 

 

 

*The maximum temperature listed is based on the ATEX standard for T4 temperature classification. If you are operating in a non-explosive environment, FKM fluoroelastomer’s maximum fluid temperature in aluminum or stainless steel pumps is 320°F (160°C).