Spray Without Air - Clear Clog
1.Relieve Pressure, page 10.
2.Rotate SwitchTip to Clear position. Aim applicator at floor and turn pump ON. When clog clears, turn pump OFF.
Setup
4.Turn air valve OFF. Connect applicator to material hose and air hose. Air supply minimum require- ments vary with material thickness and desired thickness.
ti11714a
3.Rotate SwitchTip to Spray position. Turn pump ON. Spray test pattern.
ti11715a
ti21037a
NOTICE
DO NOT USE MATERIALS THAT CURE RAPIDLY! Materials with a fast curing time could plug the pump hose, gun, or applicator.
5. Turn on/off switch ON.
Air Assisted Spray (Base Coat Applicator)
1.Prepare material, page 13. Place material hose in supply pail.
2.Turn on/off switch OFF.
ti10796b
3. Remove cap and install air valve assembly.
ti13647a
ti10795b
6.Hold applicator over material pail and turn pump ON using applicator switch on hose.
ti13641a
7.Turn pump control clockwise until desired material delivery rate is achieved.
ti8794ati5251a
313888E | 15 |