Maintenance

Replace Blades

If glass is not getting cut properly, verify the tension is correct before replacing the blades.

1.Follow Pressure Relief Procedure found within the RS Gun and Cutter, Operation-Repair manual.

2.Engage trigger lock.

3.Remove cover (627). See page 20.

Blades are sharp. Always wear protective gloves to prevent cuts when the cutter cover is removed.

4.Press and hold lock button (AK) to prevent cutter head (AA) from spinning.

5.Loosen the cutter clamp screw and remove the cut- ter head clamp.

6.Replace blades.

NOTE: Ensure the blades are all seated on the angled face of the cutter head base.

7.Replace cutter head clamp with blades.

8.Tighten the cutter clamp screw.

9.Install cover and knob.

NOTICE

More tension between the anvil and blades leads to the anvil and blades wearing out faster. To prevent premature wear and to maximize anvil and blade life, use the minimum tension required to cut the glass and make small increases in tension when strands are not cut correctly.

10.Adjust Anvil to Cutter Head Tension, page 8.

FIG. 6

NOTICE

The cutter head may be higher than the anvil quarter turn lock surface due to incorrect blade installation and may result in blade damage. Perform Replace Blades and verify all blade installations are correct.

FIG. 7

12

332574D

Page 12
Image 12
Graco 332574D important safety instructions Replace Blades