Installation
Installation
Description
The heated hose maintains proper fluid temperature while dispensing.
Fluid hoses are marked with red tape for ISO/hard- ener/minor volume side, blue tape for RES/resin/major volume side. Fittings have different sized threads to pre- vent incorrect connection, which can cause fluid cross- over and permanently damage the hose.
Hoses are 5 ft (1.5 m), 10 ft (3 m), 25 ft (7.6 m), and 50 ft (15.2 m) long. The whip hose is 5 ft (1.5 m) or 10 ft (3 m) long.
Connect Whip Hose to Gun or Gun Manifold
NOTE: For best whip hose flexibility, assemble whip hose to gun or gun manifold as instructed.
1.Assemble A and B component hoses to gun or gun manifold fittings as shown in FIG. 1 and FIG. 2.
2.If applicable, assemble signal cable (E1) and air hose to gun or gun manifold fittings.
3.Tighten fittings to A and B component hoses. Ensure hose remains flat after fittings are tightened. Loosen and retighten fittings as necessary to elimi- nate any torque on hoses. This will help achieve a flat profile on the hose.
NOTE: Use chemical connection kit (153) on all MD2 valves. See FIG. 2.
4.For MD2 valves with 255208 and 255249 and both EP Gun models, connect the signal cable (E1) from the applicator to the whip hose signal cable (3b).
5.See applicator manual for complete setup instruc- tions.
Tighten
Tighten
Tighten
FIG. 1: Fusion Gun
153c | B Side Hose | |
3b | ||
| ||
| E1 | |
| A Side Hose |
153a
153b 153a
r_24d501_3a0237_1a
FIG. 2: MD2 Valve Kit 24D501
16 | 3A0237L |