Connect FTS and Heated Whip Hose

Installation

Connect FTS and Heated Whip Hose

NOTICE

To prevent damage to probe, do not kink or exces- sively bend hose. Do not coil hose tighter than the minimum bend radius of 3 ft (0.9 m). Do not subject hose to excessive weight, impact, or other abuse.

1.For Single Zone Heat:

Carefully extend FTS probe (H) into the hose sec- tion from the proportioner. Do not bend or kink probe. Insert in component A (red) side of main hose for foam or polyurea systems.

For Dual Zone Heat:

Carefully extend FTS probe (H) into the hose sec- tions from the proportioner. Do not bend or kink probe. Insert in component A (red) and component B (blue) side of main hose for foam or polyurea sys- tems.

2.Connect FTS (J) to whip hose (W).

Single Zone Heat

J

R

F

3.Connect whip hose ground wire (K) to ground screw on underside of FTS.

4.Connect fluid hoses to FTS (J).

NOTE: To use 1/2 in. (13 mm) ID fluid hoses, remove the adapters from the proportioner fluid manifold and install them in the FTS swivel inlets.

5.Connect electrical connectors (D).

6.Connect air hose (C) to whip air hose (L) or see Connect Solenoid Kit on page 21 for installation instructions.

7.Connect hose assembly cable (F) to FTS cable (R). Leave slack (G) in cables as stress relief, to prevent cable failure.

8.See Check Hoses for Leaks, page 22.

D

B

K

To Gun

G

B A 1.For Single Zone Heat: H

To Proportioner

C

24

A W

3b

L

ti14735a

24D160 or 24D161, page 21

Dual Zone Heat

F

G For Dual Zone Heat:

D

To Proportioner

FIG. 13: FTS Connections

K

R J

B Single Zone Heat H

A

24

D

D B

To Gun

W

A

3b

D

L

ti14736b

C24D160 or 24D161, page 21

20

3A0237L

Page 20