Installation
Connect FTS and Heated Whip Hose
NOTICE
To prevent damage to probe, do not kink or exces- sively bend hose. Do not coil hose tighter than the minimum bend radius of 3 ft (0.9 m). Do not subject hose to excessive weight, impact, or other abuse.
1.For Single Zone Heat:
Carefully extend FTS probe (H) into the hose sec- tion from the proportioner. Do not bend or kink probe. Insert in component A (red) side of main hose for foam or polyurea systems.
For Dual Zone Heat:
Carefully extend FTS probe (H) into the hose sec- tions from the proportioner. Do not bend or kink probe. Insert in component A (red) and component B (blue) side of main hose for foam or polyurea sys- tems.
2.Connect FTS (J) to whip hose (W).
Single Zone Heat
J
R
F
3.Connect whip hose ground wire (K) to ground screw on underside of FTS.
4.Connect fluid hoses to FTS (J).
NOTE: To use 1/2 in. (13 mm) ID fluid hoses, remove the adapters from the proportioner fluid manifold and install them in the FTS swivel inlets.
5.Connect electrical connectors (D).
6.Connect air hose (C) to whip air hose (L) or see Connect Solenoid Kit on page 21 for installation instructions.
7.Connect hose assembly cable (F) to FTS cable (R). Leave slack (G) in cables as stress relief, to prevent cable failure.
8.See Check Hoses for Leaks, page 22.
D | B |
K | To Gun |
G
B A H
To Proportioner
C
24
A W
3b
L
ti14735a
24D160 or 24D161, page 21
Dual Zone Heat
F
G
D
To Proportioner
FIG. 13: FTS Connections
K
R J
B H
A
24
D
D B
To Gun
W
A
3b
D
L
ti14736b
C24D160 or 24D161, page 21
20 | 3A0237L |