Graco 3A0237L important safety instructions Check Hoses for Leaks, Protective Covering

Models: 3A0237L

1 42
Download 42 pages 55.61 Kb
Page 22
Image 22
Check Hoses for Leaks

Installation

4.For 24C757: Connect valve (201) to the B side pump guard (GD) with screws (208) and washers (209).

GD

206

209

208

201

r_24c352_3A0237_2a

FIG. 17

5.Remove motor cover and connect solenoid cable (206) to cable (2B).

2B

6.For 24D160 and 24D161: Connect the valve (201) between the last hose bundle and the whip hose with zip ties (not supplied.) See FIG. 13.

NOTE: To ensure proper operation of valve, install the solenoid kit within 15 ft (4.5 m) of the applicator. The solenoid reaction time decreases if the solenoid kit is farther away from the applicator. Ensure that the scuff guard covers the solenoid if mounted between the hose and whip hose.

Check Hoses for Leaks

1.Grease with Fusion grease and connect fluid hoses to proportioner fluid manifold (M). Red for hardener, blue for resin. See FIG. 18.

NOTE: The manifold hose adapters (N,P) allow use of 1/4 in. and 3/8 in. ID fluid hoses.

To check adapter tightness, torque as follows:

A (red) side (N) to 20-25 ft-lb (27-34 N•m).

B (blue) side (P) to 30-35 ft-lb (41-47 N•m).

To use 1/2 in. (13 mm) ID fluid hoses, remove the adapt- ers from the proportioner fluid manifold and install them in the FTS swivel inlets.

M

N Protective Covering

P

TI14737b

FIG. 18

2.For spray guns, close fluid valves on gun fluid mani- fold. Remove manifold from gun, see gun manual. Connect fluid whip hoses to manifold.

3.Check that all equipment is properly grounded. See system operation manual.

4.Pressure check hose. See proportioner manual for priming instructions. After all lines are free of air, check for leaks. If there are leaks, relieve pressure as instructed in proportioner manual. Tighten con- nections, then pressurize again to ensure leaks have stopped. Relieve pressure.

Protective Covering

1. Wrap all fluid hose connections with electrical tape.

TI14738a

FIG. 19

2.Fold wire back on hose to ensure adequate strain relief. Wrap all electrical connections and cable con- nections with electrical tape to protect them from pulling apart and abrasion.

3.Install protective cover, or wrap hose bundle with duct tape to protect foam.

4.For hoses that include a protective scuff cover, unroll excess cover over hose and electrical connec- tions. Tape securely.

22