Display Module

26 3A0869H

Ranges for User Inputs

This table is a one-sheet reference of the data range accepted for each user input. See the page indicated in the

table for further screen information, if needed.

Page Screen User Input Range/Options Default
42 Run Mix Batch (3) Target Volume 1 to 9999 cc 0 cc
43 Run Job Number User Number 000000000 to 999999999 000000000
45 Password (16) Password 0000 to 9999 0000 (disabled)
46 Configure 1 (18) System Type Meters; 50cc Pump; 75cc Pump; 100cc
Pump; 125cc Pump; 150cc Pump
Meters
46 Configure 1 (18) Dosing Type Dynamic (A B)
50cc Sequential (A-B 50cc)
100cc Sequential (A-B 100cc)
50 cc Sequential
46 Configure 1 (18) Gun Flush Box Enable On or Off Off
46 Configure 1 (18) Number of Guns 1 or 2 guns 1 gun
46 Configure 1 (18) Number of Colors 1 or 3 colors 1 color
46 Configure 2 (19) Gun 1 or Gun 2 hose length 0.1 to 45.7 m / 0.3 to 150 ft 1.53 m / 5.01 ft.
46 Configure 2 (19) Gun 1 or Gun 2 hose diameter 0.1 to 1 inch 0.25 inches
46 Configure 2 (19) Flow Rate Region High (250 cc/min or higher) or
Low (<250 cc/min)
High
46 Configure 3 (20) USB Log Language Chinese; Dutch; English; French; German;
Italian; Japanese; Korean; Portuguese;
Russian; Spanish; Swedish;
English
46 Configure 3 (20) Date Format mm/dd/yy; dd/mm/yy; yy/mm/dd mm/dd/yy
46 Configure 3 (20) Date 01/01/00 to 12/31/99 Set at factory
46 Configure 3 (20) Time 00:00 to 23:59 Set at factory
46 Configure 3 (20) Password 0000 to 9999 0000 (disabled)
46 Configure 3 (20) Backlight Timer 0 to 99 minutes 0 minutes
46 Configure 4 (21) Distance Units Feet/inches or Meters/cm Feet/inches
46 Configure 4 (21) Volume Units Liters; Gallons US; Gallons Imperial Gallons US
47 Recipe 1-1 (28)
Recipe 2-1 (30)
Recipe 3-1 (32)
Ratio 0:1 to 30:1
Note: Enter 0 to dispense A only.
1:1
47 Recipe 1-1 (28)
Recipe 2-1 (30)
Recipe 3-1 (32)
Ratio Tolerance 1 to 99 percent 5 percent
47 Recipe 1-1 (28)
Recipe 2-1 (30)
Recipe 3-1 (32)
Potlife Timer 0 to 240 minutes
Note: If set to 0, potlife alarm is disabled.
60 minutes
47 Recipe 0 (27)
Recipe 1-2 (29)
Recipe 2-2 (31)
Recipe 3-2 (33)
Flush Times - First (A purge),
Second (B purge), or Third
(using A or B, selected by user)
0 to 240 seconds
Note: If set to 0, the valve(s) will not flush.
60 seconds
48 Maintenance 1 (24) Meter A or Meter B 0 to 2,000,000 L / 0 to 528,344 gal 0
48 Maintenance 1 (24) Solvent Valve A or B 0 to 9,999,999 0
48 Maintenance 2 (25) Dose Valve A1, A2, A3, or B 0 to 9,999,999 0
48 Maintenance 3 (26) Fluid Filter A or B, or Air Filter 0 to 9999 days 0 days
49 Calibration 1 (22) Meter A1, A2, A3, or B K-Factor 0 to 0.873 cc/pulse 0.119 cc/pulse
49 Calibration 2 (23) Actual Dispensed Volume 0 to 9999 cc 0 cc