System Errors
56 3A0869H
Since the ProMix 2KE does not know it is spraying
because there is no gun trigger/air flow switch input,
it will go into System Idle every 2 minutes when in
Mix mode.

System Idle Notice (IDLE)

This warning occurs if the ProMix 2KE is set to Mix
and 2 minutes have elapsed since the system last
received the air flow switch signal (gun trigger). The Gun
Idle icon is displayed.

In applications using the AFS,

triggering the gun clears
the warning and you can start spraying again.

Without the AFS,

triggering the gun does not clear the
alarm. To start spraying again, you must press ,
then , then trigger the gun.