Setup Mode Details
48 3A0869H
Maintenance 1-3 (Screens 24-26)
Maintenance 1 (Screen 24) displays if is selected
on Setup Home (Screen 17). The Maintenance Screens
display actual and target maintenance timers for meters
and solvent valves (Maintenance 1, Screen 24), dose
valves (Maintenance 2, Screen 25), and fluid filters and
air filters (Maintenance 3, Screen 26). Timers for meters
are settable from 0 to 2,000,000 L or 0 to 528,344 gal-
lons. Timers for valves are settable from 0 to 9,999,999
counts. Timers for filters are settable from 0 to 9999
days.
• Press to move through the three mainte-
nance screens.
• Press to clear the maintenance total that is
highlighted. A confirmation screen appears. Use
to highlight and press on the to clear
the batch totals. No other button press will clear the
totals. Press on the to return to the active
Maintenance Screen without clearing.
Maintenance Recommendations
The following table shows recommended starting values
for maintenance. Maintenance needs will vary based on
individual applications and material differences.
F
IG
. 45. Setup Maintenance 1-3 (Screens 24-26)
Maintenance
actual and
target
Meters Solvent valves
Home
Fluid Filters Air filter
Maintenance 1
Maintenance 2
Maintenance 3
Dose
valves
Days
Clear totals
Component
Recommended Maintenance
Frequency
Solvent Valves 1,000,000 cycles
Fluid Filter 5 days,
daily check is recommended
Air Filter 30 days
Pumps 250,000 cycles
Dose Valves 1,000,000 cycles
Meters 5,000 gallons