System Errors
60 3A0869H
SM
MixFill Start Error
In systems with a gun flush
box, insufficient volume of
mixed material is detected
during the 10-second mixed fill
sequence.
SN
MixFill Complete Error
Insufficient volume of mixed
material is detected during the
5-minute mixed fill sequence.
Gun Flush Box is not triggering gun. Verify trigger is being pulled. Adjust as
needed.
Line or gun is plugged or restricted. Clean line, tip, or filter.
Flow rate is too low. Increase fluid pressure or decrease
restriction.
Valve is stuck. Clean valve or verify that solenoid is
triggering valve properly.
QPD1 or QPD2
Potlife Error
Potlife has been exceeded for
the mixed material for Gun 1
(QPD1) or Gun 2 (QPD2).
Have not sprayed enough volume to
keep fresh mixed fluid in the mix mani-
fold, hose, and gun.
Purge the mixed material line. See page
34.
Check that hose length and diameter
have been entered correctly. See Con-
figure 2 (Screen 19), page 46.
Spray the required volume to restart the
potlife timer.
Alarm and Description Cause Solution